Mont_1.book Page 10 Monday, March 25, 2002 10:39 AM
346.004
Environmental Condition Table
Descriptions
Working temperature
Storage temperature
GB
Relative humidity
Ambient dust
Electric connection
'$1*(5 &$87,21 (OHFWULF FRQQHF
WLRQ WR WKH SRZHU PDLQV VKRXOG EH H[HFXW
HG E\ VNLOOHG HQJLQHHUV
Check for the perfect efficiency of the plant
grounding system.
Make sure that the line voltage (V) and fre-
quency (Hz) correspond to the machine rat-
ings (refer to the machine identification plate
and wiring diagram).
The machine comes equipped with an elec-
tric cable to which a multipolar plug should
be connected.
Plug the machine into a main wall switch
with differential.
Three-phase connection
Start the machine for just a few seconds and
check that the beater turns in the right direc-
tion. If this is not the case, disconnect power
and exchange two of the three phase wires
in the plug.
Values
0÷35 °C (32÷95 °F)
-15 a +65 °C (from-6.8 to +149 °F))
maximum 80% at an ambient temperature of 20°C
maximum 50% at an ambient temperature of 20÷60°C
lower than 0.03 g/m
Single-phase connection
230V - 1Ph
ÃÃ Ã
2
INSTALLATION
3
Three-phase connection
230/400V - 3Ph
IDM-34600400601.tif