Maintenance And Fault; Maintenance; Fault Rectification; Shorten Suspension Cable - Vega VEGAWELL S 51 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance and fault rectification

5 Maintenance and fault

rectification

5.1 Maintenance

If the instrument is used properly, no special
maintenance is required in normal operation.
5.2 Fault rectification
Failure reasons
VEGAWELL S 51 offers maximum reliability.
Nevertheless, faults can occur during operation.
These may be caused by the following, e.g.:
Sensor
l
Process
l
Voltage supply
l
Signal processing
l
Fault rectification
The first measure to be taken is to check the output
signal. In many cases, the causes can be
determined this way and the faults rectified.
24 hour service hotline
Should these measures not be successful, please
call in urgent cases the VEGA service hotline under
the phone no. +49 1805 858550.
The hotline is available to you 7 days a week
round-the-clock. Since we offer this service world-
wide, the support is only available in the English
language. The service is free of charge, only the
standard telephone costs will be charged.
Checking the 4 ... 20 mA signal
Connect a handheld multimeter in the suitable
measuring range according to the wiring plan.
?
4 ... 20 mA signal not stable
no atmospheric pressure compensation
l
à
Check the capillaries and cut them clean
à
Check pressure compensation in
VEGABOX 02, if necessary clean filter
element
20
?
4 ... 20 mA signal missing
Wrong connection to power supply
l
à
Check connection according to chapter
"Connection steps" and if necessary,
correct according to chapter "Wiring plan"
No power supply
l
à
Check cables for breaks; repair if neces-
sary
Supply voltage too low or load resistance
l
too high
à
Check, adapt if necessary
In Ex applications, the regulations for the
wiring of intrinsically safe circuits must be
observed.

5.3 Shorten suspension cable

Shorten the suspension cable individually. Proceed
as follows:
Remove the filter adapter from the transparent
1
capillary line
Cut the suspension cable with an edge cutter
2
to the requested length
Caution:
Do not squeeze the capillary cable, this will
influence the pressure compensation. If
necessary, rework with a sharp knife.
Remove approx. 10 cm of the cable mantle,
3
strip off approx. 1 cm of the wire ends
Insert the filter adapter
The work steps are finished.

5.4 Instrument repair

If a repair is necessary, please proceed as follows:
You can download a return form (23 KB) from our
Internet homepage www.vega.com under: "Down-
loads - Forms and certificates - Repair form".
By doing this you help us carry out the repair
quickly and without having to call back for needed
information.
VEGAWELL S 51

Publicidad

Tabla de contenido
loading

Tabla de contenido