Sime MURELLE HE 50 R Manual De Usario página 83

Ocultar thumbs Ver también para MURELLE HE 50 R:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Type C (separate ø 80 flues)
TABLE OF LOAD LOSSES OF ACCESSORIES
90° MF polypropylene curve
45° MF polypropylene curve
Polypropylene extension L. 1000
Polypropylene extension L. 500
Coaxial roof exit terminal + Fitting (pos. 10)
Roof exit terminal L. 1381
Exhaust terminal
Air inlet terminal
Polypropylene extension L. 250 with socket
Coaxial exhaust L. 885 + Fitting (pos. 10)
Condensation recovery L. 135
KEY
1
90° MF polypropylene curve (6 pcs.) code 8077450
2 a Polypropylene extension L. 1000 (6 pcs.) code 8077351
2 b Polypropylene extension L. 500 (6 pcs.) code. 8077350
3
Hinged tile code 8091300
4
Roof terminal kit L. 1381 code 8091204
4 a Coaxial roof exit terminal code 8091205
5
Polypropylene extension L. 250 with socket code 6296513
6
45° MF polypropylene curve (6 pcs.) code 8077451
7
Exhaust terminal code 8089501
8
Internal-external ring nut kit code 8091500
9
Air inlet terminal (supplied with unit)
10
Inlet/exhaust fitting code 8091401
11
Rubber gasket ø 80 (supplied as standard)
12
Condensation recovery L. 135 code 8092800
13
Coaxial exhaust ø 80/125 L. 885 code 8091210
Type C (separate ø 80 flues and
Load loss
(mm H
O)
2
Inlet
Exhaust
0,80
0,80
0,45
0,45
0,35
0,45
0, 1 5
0,20
-
4,00
-
1,30
-
1,50
0,20
-
-
0, 1 0
-
5,00
1,80
-
WARNING:
- Installations with roof exit terminal (4a) and coaxial
exhaust (13) require the use of a condensation reco-
very (12) that has to be connected to the water drain
siphon (waste water).
- The installation of the roof exit terminal (4a) requires
the removal of the two ø 60 and ø 100 reducers.
- Before installing accessories, lubricate the internal
part of gaskets with silicon-based products. Avoid
using oils and greases.
coaxial exhaust terminal)
ES
PT
ENG
Fig. 7
83

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Murelle he 50 rm

Tabla de contenido