Section 3. Troubleshooting
Troubleshooting
PRobLEM.
No response from fixture
when power is applies.
Fixture resets but does
not respond correctly
to controller(DMX mode
operation).
Colors cannot be mixed.
Fixture does not reset
correctly.
No light, lamp cuts out
intermittently, or burns
out too quickly.
Section 4. Reference
•
Control menu
•
DMX protocol
•
Specification
Colour
MENU
BEAMER STREAM - 5R BEAM AND LASER SIMULATOR
ENGLISH VERSION
PRobAbLE cAUSE(S).
No power to fixture.
Primary fuse blown.
Secondary fuse blown.
Controller not connected.
Incorrect addressing of the fixtures.
Bad data link connection.
Conflict between tracking and vector control.
Data link not terminated.
Defective fixture or 2 devices transmitting on
link.
Random color mixing is on.
Electronic or mechanical failure.
Lamp missing or blown.
Fixture or lamp is too hot.
Press UP or DOWN to choose YES or NO, press ENTER to save
Pan
ENTER
YES for anti-clockwise rotation, NO for clockwise rotation
Press UP or DOWN to choose YES or NO, press ENTER to save
Tilt
ENTER
Press UP or DOWN to choose YES or No, press ENTER to save
ENTER
Press UP or DOWN to choose OFF or ON, press ENTER to save
Lamp
ENTER
Mode
DMX512
Mode
ENTER
Mode
Autorun
Check address setting on fixture and controller.
Insert termination plug in output of last fixture.
Bypass fixtures one at a time until normal oper-
ation is regained: unplug both connectors and
Allow fixture to cool. If problem persists, contact
YES for anti-clock rotation, NO for clockwise rotation
YES for color linear change; NO for color skip change
OFF for lamp OFF; ON for lamp ON
Receive DMX signal, press ENTER to save
Pre-program auto running, press ENTER to save
REMEdy.
Check power cables.
Replace fuse.
Replace fuse.
Connect controller.
Inspect cables and correct poor connections
and/or broken cables.
Eliminate scene cross-fade on controller .
connect them directly together.
Turn off random color mixing.
Contact service technician.
Disconnect fixture and replace lamp.
service technician.
p. 7