OPERATION

CHARGING BATTERIES

ATTENTION: To prolong the life of the batteries
and to provide optimum machine performance,
ONLY recharge the batteries after a total of 30
minutes of use or more. Do not leave batteries
discharged for lengthy periods.
BATTERY METER: When the battery meter begins to
flash, stop scrubbing and recharge batteries. When
two lights begin to flash alternately, the scrub head will
automatically raise to the transport position. This will
protect the batteries from total discharge.
The following charging instructions are intended for
battery chargers supplied with the machine. Only use
a battery charger with the following specifications to
prevent battery damage.

BATTERY CHARGER SPECIFICATIONS:

S
OUTPUT VOLTAGE - 24 VOLTS
S
OUTPUT CURRENT - 20 AMPS
S
AUTOMATIC SHUTOFF CIRCUIT
S
FOR DEEP CYCLE BATTERY CHARGING
1. Transport the machine to a well--ventilated area
for charging.
WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.
2. Park the machine on a level surface and turn the
key off.
3. Before charging the batteries, periodically check the
electrolyte level in each battery cell (Figure 19).
The electrolyte level (A) should slightly cover the
battery plates (B). Add distilled water as needed.
DO NOT OVERFILL, the fluid may expand and
overflow while charging. Replace cell caps before
charging (Figure 19).
A
B
16
FIG. 19
Home
Find... Go To..
FOR SAFETY: When servicing machine, wear
protective gloves and eye protection when
handling batteries and battery cables. Avoid
contact with battery acid.
4. Connect the charger's AC power supply cord to a
properly grounded receptacle.
5. Connect the charger's DC cord to the machine's
battery receptacle located under the recovery tank
(Figure 20). Rest the recovery tank on the support
stand to promote ventilation during charging.
FIG. 20
6. The charger will automatically begin charging and
shut off when fully charged.
NOTE: The machine will not operate once the battery
charger is connected.
ATTENTION: Do not disconnect the charger's DC
cord from the machine's receptacle when the
charger is operating. Arcing may result. If the
charger must be interrupted during charging,
disconnect the AC power supply cord first.
WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.
7. After charging, check the electrolyte level (A)
again. The level should be approximately 1 cm
(3/8") from the bottom of the fill--port (B) (Figure
21). Add distilled water if needed. DO NOT
OVERFILL.
B
A
FIG. 21