TROUBLESHOOTING - - Continued
PROBLEM
Scrub head will not lower.
No solution spray or solution spray
is uneven (Streaking occurs).
is ne en (Streaking occ rs)
Scrub head continues to disperse
water when using accessory tools.
Poor water pickup.
Excessive foam/cream appears
on the floor during ReadySpace
cleaning.
Unable to adjust brush pressure
meter in the green zone or meter
t
i th
shows no reading.
shows no reading.
Short run time.
Nobles Strivet (09- -04)
CAUSE
Wire #47 is not connected to batteries.
Low voltage interrupter activated.
Control grips not rotated.
Empty solution tank.
Wrong rear vacuum shoe installed.
Plugged spray tips.
Spray tip pattern out of alignment.
Plugged solution tank filter.
Clogged solution line.
Faulty pump or solenoid.
Rear ReadySpace vacuum shoe is
installed on scrub head.
Full recovery tank.
Worn ReadySpace rollers.
Clogged vacuum shoes.
Wrong rear vacuum shoe installed.
Clogged float shut-off screen inside
recovery tank.
Loose recovery tank drain hose cap.
Loose or disconnected vacuum hose.
Clogged vacuum hose.
Defective vacuum hose.
Recovery tank lid is not in place.
Worn tank lid gasket.
Cleaning detergents were added to
solution tank.
Worn extractor brushes.
t
Tripped circuit breaker.
Loose or broken front brush motor belt.
Low battery charge.
Defective batteries.
Batteries need maintenance.
Faulty charger.
Home
Find... Go To..
OPERATION
SOLUTION
Connect wire #47 to battery as shown
in battery cable connection label.
Recharge batteries.
Rotate control grips to activate spray.
Refill solution tank.
Install correct vacuum shoe.
Clean spray tips.
Realign spray tips.
Clean solution tank filter.
Flush plumbing system.
Contact Service Center.
Replace with extractor vacuum shoe.
Drain recovery tank.
Replace rollers.
Clean vacuum shoes.
Install correct vacuum shoe.
Clean screen.
Tighten cap.
Connect hose cuffs securely.
Remove clogged debris.
Replace vacuum hose.
Properly position lid.
Replace gasket.
Drain and rinse out solution tank and
refill with water only, do not add clean-
ing detergents.
Replace brushes.
Reset brush circuit breaker button.
Contact Service Center.
Charge batteries.
Replace batteries.
See BATTERY MAINTENANCE.
Repair or replace battery charger.