INSTALLATION CON'T.
5. Leak Testing:
1.
Turn all grill control knobs to
2.
Turn ON the home gas source.
3.
Use a clean paint brush and a 50/50 mild soap and water solution. Brush soapy solution onto areas indicated. (see Figure 9).
4.
If "growing" bubbles appear, there is a leak. Close main gas supply and re-tighten all connections. If leaks cannot be stopped
do not try to repair. Contact licensed plumber for correction.
5.
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure
testing on that system at test pressures in excess of ½ psig (3.5kPa).
6.
The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any
pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.5kPa).
16
OFF.
Figure 9
Side View
Natural Gas
Regulator
Gas Inlet Pipe