6.2.3 Set Points 5-8
This menu items allows you to view and change the parameters associated with the setpoints from 5 to 8.
The setpoints from 5 to 8 cannot be loaded from the keyboard, but they are activated and deactivated only by the
TIMERS system (paragraph 6.2.5). Unlike setpoints 1-4, they do not have any associated duration, as the activation
time is decided always and only by the TIMERS.
Like the setpoints 1-4, here too you choose the regulation mode by flow or speed (see paragraph 5.1.1) and the
setpoint values, indicated with S5 – S8.
The procedure for selection and changing is identical to the one described in the previous paragraph.
The factory values are given in chapter 8.
To simplify the use of the Timers, it is recommended to assign increasing values to the setpoints, from
Setpoint 5 to Setpoint 8 (see par. 6.2.5 and following).
6.2.4 Quick Clean
The "QuickClean" key allows you to perform a rapid wash of the system or fast recirculation, for example by cleaning,
suction, adding chemicals, and so on.
Its parameters are:
‐
setpoint in Speed %, settable between 20% and 100%;
‐
duration (execution time), settable between 1 minute and 10 hours.
The factory values are: maximum curve 100%, for ten minutes (see also chapter 8).
6.2.5 Timers
There are eight different timers on the machine, from Timer A to Timer H, each of which allows timed starting and
stopping, on a weekly basis, of a setpoint chosen from Set Points 5-8.
With a simple setting you can thus automatically carry out all the desired cycles, repeated weekly. To use this mode,
see also paragraphs 5.1.2 and 5.4.