3.1 PLACEMENT
Mount the handle, rear wheels and the two cylinder
supports. The handle must not be used for lifting the
welding machine.
Place the welding machine in a ventilated area.
Dust, dirt, and any other foreign matter entering the
welding machine can interfere with ventilation and thus
with smooth operation. Therefore, in relation to the
environment and working conditions, it is important to
keep the internal parts clean. Clean using a jet of dry,
clean air, being careful to avoid damaging the machine
in any way. Before working inside the welding machine,
make sure it is unplugged from the power mains.
Any intervention carried out inside the welding
machine must be performed by qualifi ed personnel.
3.1.1 Assembling the cooling unit (optional).
Remove the 2 cylinder supports A fastened to the rear
panel B of the welding machine. Unscrew the 2 knobs
C, slide the mobile cylinder support D back, mount the
cooling unit support E on the rear panel B and screw the
mobile cylinder support D back in using the 2 knobs C on
the bottom F of the welding machine. (See fi g.2).
B
F
A
C
10
Fig. 1
E
Fig. 2
D
Fasten the cooling unit to the support E on the rear panel
B and to the base F. (See fi g.3).
A
Fig. 3
Once the cooling unit is attached, insert the 2 red
and blue water hoses leaving the connection into the
corresponding quick fi ttings G of the unit, being especially
careful to match the colors, the power connection O into
the socket P, the service connection Q into the socket R,
the power cord H of the unit into the socket I on the power
source, and the service connection L into the connector
M on the welding machine.
Remount the 2 cylinder supports A on the panel N of the
cooling unit. (See fi g.4).
I
H
M
L
R
P
Q
O
E
B
F
A
N
G
C
Fig. 4