PERFORMANCE DATA SHEET
Base Grille Water Filtration
System
Model TIKB1/TIRFKB1
Capacity
100 Gallons
(379 Liters)
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of
Chlorine
Taste and Odor, Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the reduction
of
Lead, Mercury,
Atrazine,
Benzene,
Toxaphene,
O-Dichlorobenzene,
Cysts, Turbidity, Asbestos,
Lindane,
Tetrachloroethylene,
Endrin, Alachlor,
Chlorobenzene,
Ethylbenzene,
TTHM, MTBE and VOC.
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances
listed below. The
concentration
of the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the
permissible
limit for water leaving the system, as specified in NSF/ANSl Standards 42 and 53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Aesthetic Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
2.0 mg/L
2.0 mg/L + 10%
0.08 mg/L
**
2.0 mg/L
95.93
97.36
Particulate Class I*
85% reduction
3533333#/mL
At least 10,000 part c es/mL
22000 #/mL
11567 #/mL
99.38
99.67
Contaminant
NSF Reduction
Average
Influent
Challenge
Maximum
Average
Minimum %
Average %
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.010 mg/L
150 ug/L
0.15 mg/L + 10%
1.0 ug/L
1 ug/L
99.33
99.33
Lead: @ pH 8.5
0.010 mg/L
157 ug/L
0.15 mg/L _+10%
2.0 ug/L
1.08 ug/L
98.72
99.31
Mercury: @ pH 6.5
0.002 mg/L
0.0058 mg/L
0.006 mg/L + 10%
0.0002 mg/L
0.0002 mg/L
96.53
96.53
Mercury: @ pH 8.5
0.002 mg/L
0.0057 mg/L
0.006 mg/L _+10%
0.0002 mg/L
0.0002 mg/L
96.5
96.5
Benzene
0.005 mg/L
15 ug/L
0.015 mg/L _+10%
0.5 ug/L
0.5 ug/L
96.67
96.67
O-Dichlorobenzene
0.6 mg/L
1750 ug/L
1.8 _+ 10%
1.0 ug/L
1.0 ug/L
99.94
99.94
Toxaphene
0.003 mg/L
15 ug/L
0.015 _+10%
1.0 ug/L
1.0 ug/L
93.33
93.33
Atrazine
0.003 mg/L
10 ug/L
0.009 mg/L _+10%
2 ug/L
2 ug/L
80.8
80.8
Asbestos
99%
101 MFL
107to 108fibers/L tt
0.17 MFL
0.17 MFL
99.83
99.83
Live Cysts _
>99.95%
120,000/L
50,000/L min.
8/U
1/U
99.99
>99.99
Turbidity
0.5 NTU
11.4 NTU
11 _+1 NTU
0.41 NTU
0.24 NTU
96.4
97.89
Alachlor
0.002 mg/L
41.3 ug/L
0.04 _+10%
0.2 ug/L
0.2 ug/L
99.52
99.52
Endrin
0.002 mg/L
5.9 ug/L
0.006 _+10%
0.5 ug/L
0.3 ug/L
91.5
95.47
Ethylbenzene
0.7 mg/L
1867 ug/L
2.1 _+10%
0.70 ug/L
0.0588 ug/L
99.96
100
Lindane
0.002 mg/L
1.9 ug/L
0.002 _+10%
0.02 ug/L
0.02 ug/L
98.93
98.93
Chlorobenzene
0.6 mg/L
2.0 ug/L
2.0 _+10%
0.0005 ug/L
0.0005 ug/L
99.98
99.98
Tetrachloroethylene
0.005 mg/L
14.2 ug/L
0.015 _+10%
0.5 ug/L
0.5 ug/L
96.47
96.47
TTHM
0.080 mg/L
465 ug/L
0.45 _+20%
1.0 ug/L
0.5 ug/L
99.78
99.88
MTBE
0.005 mg/L
14 ug/L
0.015 _+20%
0.70 ug/L
0.52 ug/L
94.94
96.27
VOC
0.015 mg/L
0.3520 mg/L
0.300 _+10%
0.0060 mg/L
0.0008 mg/L
98.4
99.78
Test Parameters:
pH = 7.5 _+0.5 unless otherwise
noted.
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service
capacity
= 100 gallons
(379 liters).
•
It is essential
that operational,
maintenance,
and filter
•
replacement
requirements
be carried
out for the product
to
perform
as advertised.
•
Model
T1KBI"
The filter monitor
system measures the amount
of
water that passes through
the filter and alerts you to replace the
filter.
Style
1 - When the filter indicator
reads 10%, order a new filter.
When the indicator
reads 0%, it is recommended
that you
replace the filter.
Style 2 - When the filter indicator
changes
from green to yellow,
order a new filter. When the indicator
changes
from yellow to red,
it is recommended
that you replace the filter.
Style 3 - When the water filter status display
changes
from
"GOOD"
to "ORDER,"
order a new filter. When the filter indicator
reads "REPLACE,"
it is recommended
that you replace the filter.
Use replacement
cartridge
T1 RFKB1, part #9030.
2008 suggested
retail price of $59.99
U.S.A./S71.99
Canada.
Prices are subject
to change without
notice.
•
These contaminants
are not necessarily
in your water supply.
While testing
was performed
under standard
laboratory
conditions,
actual performance
may vary.
•
The product
is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown
quality without
adequate
disinfection
before or after the
system.
Systems
certified
for cyst reduction
may be used on
disinfected
waters that may contain
filterable
cysts.
•
Refer to the "Warranty"
section
for the Manufacturer's
name,
address
and telephone
number.
•
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm (1.9 L/min) @ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL
of AC Fine Test Dust.
ttFibers greater than 10 um in length
€Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark of NSF International.