Daikin DX17vS Instrucciones De Instalación página 12

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

c
r
alculate
efrIgerant
The condenser unit is shipped with a predetermined factory charge level as shown below. For longer line sets greater than
15 ft. (Detail shown in tables on page 12) add 0.6 ounce of refrigerant per foot. Refer to the following page for the equivalent
length of the elbow fittings.
total refriger-
factory charge
=
ant (A)
(A) to (C) parameters are calculated/followed below.
(A) There is 2 way calculation for total refrigerant amount
(A)-1
Select line set length from (A)-1 table.
(A)-2
Calculate from above formula by using (B), (C)-1 and (C)-2 factors.
(B) Pick up from name plate which has factory charge amount.
(C) Calculate above formula. (C)-1 and (C)-2 shown below.
Subtract factory charge length (see (A)-1 Table) from the overall length and put the results in
Additional Charge for
liquid line (C)-1
Adjust amount from
suction line (C)-2
charge table for total/Additional refrigerant (A)-1
Actual Line Set Length (ft.)
Liquid Line Diameter (inch)
Suction Line Diameter (inch)
Total/Additional
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
c
B
harge
aSed on
+
(B)
= [for liquid line (c)-1] – [Adjust amount from suction line (c)-2]
=
(3/8" liquid line)
Check the suction line diameter and
=
pick the adjust amount (oz.)
3.5/4.0 Ton
5.0 Ton
Total refrigerant (oz.)
3/8"
1 1/8"
Total
Additional
Total
116
0
139
119
3
142
122
6
145
125
9
148
128
12
151
131
15
154
134
18
157
137
21
160
140
24
163
143
27
166
146
30
169
149
33
172
152
36
175
155
39
178
158
42
181
161
45
184
164
48
187
167
51
190
Factory Charge
l
S
l
Ine
et
ength
Additional charge (c)
ft. x 0.6 oz.
Additional
0
3
6
9
12
15
18
21
24
27
30
33
36
39
42
45
48
51
12
12
ft.

Publicidad

Tabla de contenido
loading

Tabla de contenido