Daikin DX17vS Instrucciones De Instalación página 32

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SUBMENU ITEM
CL Reset
Cool Airflow Trim Hi
Cool Airflow Trim Int
Cool Airflow Trim Low
Cool Airflow Profile
Cool ON Delay
Cool OFF Delay
Dehumidification Select
SUBMENU ITEM
Maximum Compressor RPS Range
for Cooling
(COOL RPS RANGE)
Maximum Compressor RPS Selec-
tion for Cooling
(COOL RPS SELECT)
cool SetUP
USER MODIFIABLE OPTIONS
YES or NO
-15% to +15% in 3% increments
-15% to +15% in 3% increments
-15% to +15% in 3% increments
A, B, C, or D
5, 10, 20, 30 seconds
30, 60, 90, 120 seconds
ON or OFF
Set coolinG rUn vAlUeS (cl rUn vAlUeS)
USER MODIFIABLE OPTIONS
Five different compressor RPS
ranges will be provided.
10 compressor RPS values will be
provided within the range selected
in the COOL RPS RANGE menu.
32
32
COMMENTS
Selecting to default factory setting.
Selects the cooling airflow trim amount.
Selects the cooling airflow trim amount.
Selects the cooling airflow trim amount.
Selects the cooling airflow profile.
Selects the indoor blower ON delay.
Selects the indoor blower OFF delay.
Selecting "OFF" disables dehumidification; selecting
"ON" enables dehumidification.
COMMENTS
Select the appropriate range for the installed system
configuration.
Select the appropriate compressor RPS for the
installed system configuration.

Publicidad

Tabla de contenido
loading

Tabla de contenido