4. FREEROLL RTS: Fit the unit to the wall and wire the control unit
. Fit the FREEROLL unit to wall.
. Unplug the test lead from the motor.
. Connect the 4-wires from the motor to the FREEROLL (refer to wiring diagram).
. Connect the FREEROLL to the Mains.
. Fit the cover.
5. Wire and Fit the Safety Edge Transmitter
. Connect the resistive safety edge connector to the 2 pin connector on the board of the Safety Edge
Transmitter cover.
. Fit the cover of the Safety Edge Transmitter.
6. Commissioning
. Press the
button on the cover to move the door to the open end-limit position.
. Press the
button on the cover to close the door completely without pressing the safety edge.
. Then reopen pressing the
. Press the
button on the cover to close the door and test that the safety edge is working simulating
an obstacle.
THE COMMISSIONING PHASE IS COMPLETE – THE FREEROLL RTS CONTROL SYSTEM IS
NOW READY-TO-USE.
button.
27