Installation Step 8:
ELECTRICAL WARNING
•
To reduce the risk of electrical shock, this equipment has
a grounding type Plug that has a third (grounding) Pin.
This Plug will only fit into a grounding type outlet. If the
Plug does not fit into the outlet, contact a qualified
electrician to install the proper outlet. Do Not change
the Plug in any way.The door Opener must be properly
grounded to prevent personal injury and damage to the
components.
•
The electrical power to the door Opener Must Be removed
when the Motor Cover is removed. Electrical power must
remain off while making electrical connections.
A
Check building codes:
•
If building code requires Opener be permanently wired
to building, have a licensed electrician perform step B.
•
If you are not installing permanent wiring, go to step C.
B
Instructions for licensed electrician - connecting power
with permanent wiring (Figure 32):
•
Remove power from circuit.
•
Remove Motor Cover.
•
Remove and discard Power Cord.
–
Cut off Power Cord inside Power Head as near Strain
Relief as possible.
–
Remove Knock-Out Plug, Strain Relief, and Power
Cord. (Cut Ground Wire on line side of Toroid).
–
Dispose of Plug, Strain Relief, and Power Cord.
•
Install required entrance bushing.
•
Connect permanent wiring to Power Head Wires.
–
White supply line to Opener White Wire.
–
Black supply line to Opener Black Wire.
–
Ground to Opener Green Wire.
–
Replace Motor Cover.
Use only Underwriters Laboratories, Inc. (U.L.)
•
recognized wire nuts.
The Circuit Boards are light sensitive. Ensure the
•
Motor Cover is installed before energizing
the Opener.
–
Restore Power to circuit.
C
Connecting Power with Plug:
•
Plug Opener into a grounded outlet as stated in previous
electrical warning.
D
Perform Safe-T-Beam® alignment check:
•
Check if Safe-T-Beam® Source Red LED is glowing
continuously (OK) or blinking (problem).
•
If Red LED is blinking twice, adjust Sensor Brackets as
needed to make Red LED glow continuously. (Refer to
page 26.)
For Help, call 1-800-35-GENIE or visit www.geniecompany.com