To protect your new investment, your Excelerator® is
equipped with a Timer and Cycle Counter which work
together to prevent any chance of heat damage to
electrical circuits caused by too many cycles in too short
a time. If your Opener suddenly stops responding to the
Wall Console - Do Not Unplug the Unit - simply wait
10 minutes for the Timer/Cycle Counter to reset itself
and try again.
•
Unplugging the unit will prevent the Timer/Cycle
Counter from resetting.
D
Test Door Opener:
•
Run door up and down a few times using Wall Console
and observe door travel.
•
Repeat steps above as needed to set Limit
Switch positions.
E
Adjust Open Force to minimum needed:
•
Place door in closed position using Wall Console.
•
Gently adjust Open Force fully counterclockwise
(minimum force).
•
Run Opener using Wall Console.
•
Observe that door runs to Open Limit Switch.
–
If not, adjust Open Force Control slightly clockwise,
close garage door, and open it again.
•
Repeat steps above until garage door runs smoothly
from Close Limit Switch to Open Limit Switch.
F
Adjust Close Force to minimum needed:
•
Place door in open position using Wall Console.
•
Gently adjust Close Force fully counterclockwise
(minimum force).
•
Run Opener using Wall Console.
•
Observe that door runs to Close Limit Switch.
–
If not, adjust Close Force Control slightly clockwise,
open garage door, and close it again.
•
Repeat steps above until garage door runs smoothly
from Open Limit Switch to Close Limit Switch.
C
H
Installation Step 10:
Limit Switch and Force Adjustments must be completed
before checking the contact reverse function (Figure 35).
A
Open garage door using Wall Console.
B
Lay a 2" x 4" board flat in center of doorway.
C
Close door using Wall Console.
D
Check that door stops and reverses within 2 seconds after it
contacts board:
•
If door does not reverse, decrease Close Force until
door reverses.
•
If door still does not reverse, move Limit Switch
toward door.
E
Check Safe-T-Beam® System operation:
•
If beam is blocked, door will not close.
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
NOTE
S
C
ETTING
ONTACT
R
F
EVERSE
UNCTION
NOTE
NOTE
The door must contact the 2" x 4" board before the
Carriage activates the Close Limit Switch. If not,
readjust the Close Limit Switch.
2" x 4" board
laid flat
Figure 35 Checking Contact Reverse
21