A40
Connecting to 12 Vg
I
NOTE
You cannot set the temperature with the thermostat control
during battery operation. The device is simply switched on
and starts cooling.
Disconnect the cooler from the battery when the engine is not
running as otherwise the battery will be completely run down.
➤ Make sure that the cable from the battery to the cooler is protected by
a fuse (max. 8 A).
➤ Select a cable cross section for the cable between the battery and the
socket of the 12 V voltage supply in accordance with the following table:
Cable length
Up to 2.5 m
2.5 m to 4.0 m
➤ Make sure that the thermostat control for 220 V – 240 V operation
(fig. 2 2, page 3) is in the "0" position.
➤ Insert the plug of the connection cable into the 12 V socket
(e.g. cigarette lighter).
The polarity cannot be reversed.
➤ To switch off the cooler, pull the plug out of the socket.
Connecting to a gas source
!
WARNING!
The operation of gas appliances whilst the vehicle is in motion
must be in accordance with national guidelines.
Only use propane or butane gas cylinders with an approved
pressure reduction valve and suitable top part.
Compare the pressure information on the type plate with the
pressure information on the propane or butane gas cylinder.
Never place the device near flammable materials (paper, dry
leaves, textiles).
Your connecting hose must be replaced in accordance with
national guidelines.
Only use approved hose lines (DIN 4815 part 2) with a maxi-
mum length of 1.5 m (in Finland 1.2 m).
EN
Operating the cooler
Cable cross section
2.5 mm²
4.0 mm²
13