Use batterycharger plug to keepthe battery chargedand ready
for use. Batterycharging should be done in a dry location.
1. Plug charger into "Battery ChargerInput"jack, located on the
control panel.Plug wall receptacleend of the battery charger
into a 120 Volt AC walt outlet.
2. Unplugbattery chargerfrom walt outlet and control paneljack
when generatoris going to be in use.
NOTE:
Do not use the battery chargerfor more than 48 hoursat one
charge.
3.1 MAINTENANCE
SCHEDULE
Follow the calendar intervals. More frequent service is required
when operatingin adverseconditions noted below.
CheckOil Level
ChangeOil and Oil Filter:!:
CleanSparkArrestor Screen
Service Air Filter
ReplaceSpark Plug
$
"k
At Each Use
*Every Season/Every100 Hours
**Every Season/Every100 Hours
**Every Season/Every200 Hours
Every Season
Changeoil after first 30 hours of operation then every season.
Changeoil and oil filter every month when operating under heavy load or in
high temperatures.
Clean more often under dirty or dusty operating conditions. Replaceair filter
parts if very dirty.
3.2 PRODUCT SPECIFICATIONS
3.2.1 GENERATOR S PEC/F/CATIONS
Model # ...................................................................... 005800, 005747
RatedMax. Power................................................................... 8.0 kW**
Surge Power................................................................................ 10 kW
RatedAC Voltage...................................................................... 120/240
RatedMax AC Load
Current @ 240V............................................................. 33.3 Amps**
Current @ 120V............................................................. 66.7 Amps**
RatedFrequency.................................................... 60 Hz @ 3600 RPM
Phase................................................................................ SinglePhase
RatedDCVoltage...................................................................... 12 Volts
BatteryType.................................................................... 10 AH, 12VDC
Model # ...................................................................... 005797, 005798
RatedMax. Power................................................................... 7.0 kW**
Surge Power............................................................................. 8.75 kW
RatedAC Voltage...................................................................... 120/240
RatedMax AC Load
Current@ 240V............................................................. 29.2 Amps**
Current@ 120V............................................................. 58.3 Amps**
RatedFrequency.................................................... 60 Hz @ 3600 RPM
Phase................................................................................ SinglePhase
RatedDCVoltage...................................................................... 12 Volts
BatteryType.................................................................... 10 AH, 12VDC
Model # .................................................................................... 005796
RatedMax. Power................................................................... 6.5 kW**
Surge Power............................................................................. 8.13 kW
RatedAC Voltage...................................................................... 120/240
RatedMax AC Load
Current @ 240V............................................................. 27.1 Amps**
Current @ 120V............................................................. 54.2 Amps**
RatedFrequency.................................................... 60 Hz @ 3600 RPM
Phase................................................................................ SinglePhase
RatedDCVoltage...................................................................... 12 Volts
** Maximum wattage andcurrent a resubject t o, andlimitedby,suchfactors
asfuelBtucontent, a mbient t emperature, altitude, e nginecondition, e tc..
Maximum powerdecreases a bout 3 .5%for each1,000feetabove sealevel;
andwill alsodecrease a bout1%for each6° C (10° F)above16° C(60° F)
ambient t emperature.
3.2.2 ENGINE SPEC/F/CATiONS
RatedHorsepower @ 3600 RPM.................................................... 14.5
Displacement............................................................................... 410cc
Spark Plug Type................................... ChampionRC14YCor Equivalent
Spark Plug Part No.................................................................... 0E7585
Spark Plug Gap............................................... 0.030 inch or (0.76 mm)
GasolineCapacity............................................................ 9 U.S. gallons
Oil Type .................................... SeeChart in "Adding Engine Oil"Section
Oil Capacity ................................................ w/Filter Change = 1.5 Qts.
w/o FilterChange = 1.2 Qts.
Oil FilterPart No...................................................................... 070185B
Run Time/FuelConsumption-l/2 Load .. 10 Hours/ .73 gallons per hour
Class II EmissionCertified
3.2.3 EMISSIONS/NFORMATiON
The Environmental Protection Agency (EPA) requires that this
generatorcomply with exhaustandevaporativeemissionstandards.
This generator is certified to meet the applicable EPA emission
levels on gasoline.The emission control system on this generator
consists of the following:
• FuelSystem
• Air Induction System
Carburetor
-
IntakePipe/manifold
Fuel T ank!cap
-
Air Filter
Fuel L ines
* Ignition System
Evaporative VentLines
_ Sparkplug
ExhaustSystem
-
Ignition module
Exhaust Manifold
• ExhaustSystem
Muffler
_ Exhaust Manifold
It is importantto perform the service specifiedin the Maintenance
Scheduleto ensurethat the generatorcomplies with the applicable
emission standards for the duration of its useful life. Additionally,
emissions critical maintenancemust be performed as scheduled
in order for the Emissions Warrantyto be valid. Emissions critical
maintenanceconsists of servicing the air filter and spark plugs in
accordance with the MaintenanceSchedule. Service and repairs
may be performed by any capableperson or repair shop.
12