The 12Va.c./d.c. power supply can be obtained from outputs 13-16
of the 485/232 Compass system, which can supply up to 2 Seletto
pushbutton panels.
For further information, refer to the specific instructions for Compass
use.
EXAMPLE FOR ENTERING A CODE INTO A COMPASS 485 SYSTEM:
Enter the required code, i.e. 741258.
1)turn ON dip switch n.6 of the COMPASS 485 board.
2)type a 6-figure number of your choice, i.e. 123456 (this beco-
mes the master card +).
3)turn OFF dip switch n.6.
4)type code 123456 (card +) then immediately afterwards the
required code 741258 (within the time allowed by Compass
485 (5s)).
5)now just type code 741258 to energise the opening contact
for the COMPASS 485 board. (terminals DOOR 3-4 JP1).
Proceed as described in point 2 for entering any further code.
For the other functions described in the instructions for COM-
PASS 485, also produce the MASTER CARD and MASTER
CARD JOLLY, repeating from steps 1-2-3 in the example, and
turning ON dip switches 7 and 8 respectively.
7)SELETTO PUSHBUTTON PANEL IN A SERIAL SYSTEM (DIP1 OFF)

7.1) Preliminary checks

The access point to be controlled by means of the pushbutton panel
must necessarily be provided with a control panel having serial inputs
and outputs.
Moreover, the control panel must be set to SLAVE, and have a
Zone address other than 0.
In the case where it is necessary to control more than one access
point by means of the pushbutton panel, connect the other control
units, still set to SLAVE and still having a Zone address other than
0, by means of the serial line. Control units with an identical zone
address answer to the same code,
The 24Va.c./d.c. power supply can be drawn from outputs "24Va.
c./d.c. – Power supply for accessories" on the control panel.
Check maximum absorption of the devices connected.
The entry of a valid code causes a START command to be sent
along the serial line. Further entries of the same code will cause
further START commands to be sent.
The operator will behave differently depending on the function logic
set on the control panel (2/3/4 steps),
For further information, refer to the specific instructions for control
panel use.
Following the diagram in Fig. 3, proceed to wire the serial line of the
control panels managed by the SELETTO pushbutton panel, exclusively
using a telephone-type line.
In the case where a telephone cable has several pairs of wires, it is
indispensable to use the wires from the same pair.
The length of the telephone cable between one appliance and the
next must not exceed 250 m.
7.2) Programming of activation codes (DIP2 OFF)
The Enter function is obtained by simultaneously pressing key 0 and
key 8. Programming can only be carried out when the pushbutton panel
is supplied with power.
1
Press Enter (0+8) N times, where N represents the number of figures
wanted to make up the activation code (from 3 to 6 figures).
2
Type the memory location used by the code (from 0 to 15) and
press Enter (0+8). A maximum of 16 different codes are therefore
possible.
3
Type the number of the serial zone be controlled with the code (from
1 to 127) and press Enter (0+8). Do not enter value 0.
4
Enter the activation code, having 3 to 6 figures (see point 1), and
press Enter (0+8).
5
If Enter (0+8) is pressed again within 10s, the procedure is resumed
from point 2 (entering position⇒zone⇒code).
For example. to attribute code 88776 to position 12, in order to activate
serial zone address 2, proceed as follows:
1
Press Enter (0+8) 5 times
2
Type 12 (location number) and press Enter (0+8)
3
Type 2 (zone number) and press Enter (0+8)
4
Type 88776 (access code) and press Enter (0+8)
5
To end programming, press any key or wait for 10s.
At the end of programming, reposition DIP2 to ON.
6 - SELETTO- Ver. 04
INSTALLATION MANUAL
www.BFTGateOpeners.com | (800) 878-7829
7.3) Making changes to a pushbutton panel already programmed
(DIP2 OFF)
Note: To be able to add codes and/or change pushbutton panel
programming, it is indispensable to know at least one valid code
number.
7.3.1) Addition of new codes
1
Press Enter (0+8) 3 times.
2
Type a valid code number entered in the memory and press Enter
(0+8).
3
Type the memory location taken up by the code to be added (from
0 to 15) and press Enter (0+8). Using a location already taken up
causes the previous code to be cancelled.
4
Type the number of the serial zone to be controlled with the code
(from 1 to 127) and press Enter (0+8). Do not enter value 0.
5
Enter the activation code, having 3 to 6 figures, depending on the
number of figures set in the first programming phase (par. 7.2), and
press Enter (0+8).
6
If Enter is pressed again, the procedure is resumed from point 3
(entering position⇒zone⇒code).
7
To end programming, press any key or wait for 10s.
7.3.2) Cancellation of codes
This operation is used to cancel all the previously programmed codes
and settings from the memory.
1
Press Enter (0+8) 4 times.
2
Type a valid code number.
3
Press Enter (0+8) and keep it pressed for at least 10s.
4
It is now possible to proceed to a new programming procedure (see
par. 7.2).
At the end of programming, reposition DIP2 to ON.
8) WARNING
1) Waiting over 10s between typing one figure and the next causes
the entry to be cancelled, and therefore it must be repeated.
2) The acoustic signal can emit 3 types of sounds:
brief single sound
long sound
brief continuous sound
3) After consecutive entry of 5 invalid codes, the acoustic signal emits
the error sound for 60s, during which time no other attempts at access
can be made. Any further incorrect code causes other error signals
to be emitted, with consequent waiting time.
4) Record the code numbers entered, especially in the case of instal-
lations having numerous access codes. The table in Fig. 5 can be
filled in and given to the user. Keep these instructions and the access
codes in a safe place which is only known to authorised persons.
9) MAINTENANCE
Installation maintenance must exclusively be carried out by qua-
lified personnel.
10) DISPOSAL
ATTENTION: disposal should only be carried out by qualified
personnel.
Materials must be disposed of in conformity with the current regula-
tions.
In case of disposal, the system components do not entail any particular
risks or danger. In case of recovered materials, these should be sorted
out by type (electrical components, copper, aluminium, plastic etc.).
The descriptions and illustrations contained in the present manual
are not binding. The Company reserves the right to make any alte-
rations deemed appropriate for the technical, manufacturing and
commercial improvement of the product, while leaving its essential
features unchanged, at any time and without undertaking to update
the present publication.
= number entered
= Enter (0+8) typed
= error (function not valid)