Dometic FreshWell 2000
Problem
Cause
Under-bench air
No supply voltage (230 Vw) con-
conditioner does
nected.
not switch on.
The voltage is too low (under
200 Vw).
The voltage converter is defective.
The defective thermal protection is
defective.
The condenser fan is damaged.
The compressor is damaged.
The electrical fuse of the power
supply is too low.
Under-bench air
The air filter is obstructed.
conditioner stops
The voltage is too low (under
working.
200 Vw).
The voltage converter is defective.
The defective thermal protection is
defective.
The condenser fan is damaged.
The heat exchange coils are polluted.
The external blower is defective.
Under-bench air
One of the temperature sensors is
conditioner does
defective.
not switch off.
The electrical fuse of the power sup-
ply is too low.
11

Warranty

The statutory warranty period applies. If the product is defective, please con-
tact the service partner in your country (addresses on the back on the instruc-
tion manual).
Our experts will be happy to help you and will discuss the warranty process
with you in more detail.
EN
Remedy
➤ Check the power supply.
➤ Contact an authorised work-
shop.
➤ Check the electrical fuse of the
power supply.
➤ Clean the air filter.
➤ Contact an authorised work-
shop.
➤ Contact an authorised work-
shop.
➤ Check the electrical fuse of the
power supply.