Maintenance Schedule - Ingersoll Rand 2000 Manual Del Usuario

Compresores de aire alternativos en dos etapas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BREATHER/UNLOADER BY-PASS
The breather/unloader by-pass tube lines eliminates air pressure build-
up in the compressor frame by providing a passage for the air to
escape through the inlet unloader (if opened) or (if closed) through the
check valve, therefore, by-passing the inlet unloader and escaping to
atmosphere through the inlet filter/silencer.
OIL CONSUMPTION CHECK
A rule of thumb in determining a "passing grade" for oil consumption is
to consider consumption at or above 50 horsepower-hours per ounce
to be acceptable.
The formula is as follows:
Horsepower
X
Hours of Operation
Ounces of Oil Used
To apply this formula, consider the size of the machine. In the following
example, a 5 horsepower compressor uses 2 ounces of oil every
20 hours of operation.
5 Horsepower
X
20 Hours of
Operation
2 Ounces of Oil Used
The compressor in the example passes the oil consumption test.
NOTE
New or rebuilt compressor pumps will
discharge higher than normal amounts of oil
until the piston rings are seated
(approximately 100 operating hours).
MAINTENANCE
Before performing maintenance, release air
aWARNING
pressure from the system and disconnect,
lock and tag the main power supply or
disconnect the wire from the engine spark
plug.
NOTE
All compressed air systems contain
maintenance parts (e.g. lubricating oil, filters,
separators) which are periodically replaced.
These used parts may be, or may contain,
substances that are regulated and must be
disposed of in accordance with local, state,
and federal laws and regulations.
NOTE
Take note of the positions and locations of
parts during disassembly to make
reassembly easier. The assembly sequences
and parts illustrated may differ for your
particular unit.
NOTE
Any service operations not explained in this
manual should be performed by an authorized
service representative.
NOTE
The following maintenance schedule has been
developed for typical applications.
Maintenance intervals should be shortened in
harsher environments.
RELEASED 05/Apr/2018 15:16:09 GMT
8
=
Horsepower Hours
per Ounce
=
50 Horsepower
Hours per Ounce
http://air.irco.com

MAINTENANCE SCHEDULE

Check for oil leaks.
Daily or Before
Check lubricant level. Fill as needed.
Each
Drain receiver tank condensate (if automatic
Operation
draining device is not provided). Open manual
drain valve and collect and dispose of
condensate accordingly.
Test drain valve for proper operation.
Clean filter screen if needed.
Check for unusual noise and vibration.
Ensure beltguards and covers are securely in
place.
Ensure area around compressor is free from
rags, tools, debris, and flammable or explosive
materials.
Check system oil pressure on pressure
lubricated models while compressor is hot.
Weekly
Observe operation of safety/relief valves while
the compressor is running. Replace safety/
relief valves that do not operate freely.
Inspect air filter element(s). Clean if necessary.
Monthly
Inspect for air leaks. Squirt soapy water
around joints during compressor operation
and watch for bubbles.
Check tightness of screws and bolts. Tighten
as needed.
Inspect drive belts. Adjust if necessary.
Clean exterior.
Clean drain valve filter screen.
3/500 *
Change petroleum lubricant while crankcase
is warm.
Drain compressor oil and clean oil sight glass
6/1000 *
Replace oil filter and change lubricant (if
necessary) on pressure lubricated modles.
12/2000 *
Change synthetic lubricant while crankcase
is warm.
Replace filter element
* indicates months/operating hours, whichever occurs first.
FILTER INSPECTION & CLEANING
1. Loosen the clamps securing the filter housing to its base.
2. Remove the filter housing and withdraw the old filter element.
Clean the element with a jet of air or vacuum.
3. Replace the filter element and housing.
81295669
OIL CHANGE
1. Remove the oil drain plug and allow the lubricant to drain into a
suitable container.
2. Replace the oil drain plug.
3. Follow the filling procedures in INSTALLATION section.
81295651