Technical data
Output data for charging
Charging current:
Maximum output voltage:
Reference temperature
Battery temperature
compensation:
Temperature compensation
range:
DSP-EM
Ref. no.:
Input voltage:
Power consumption
In display mode:
In standby mode:
Dimensions:
Certification:
For the current EU declaration of conformity for your device please refer to the
respective product page on dometic.com or contact the manufacturer directly (see
back page).
32
DSP1212C
DSP2012C
12.5 A/25 A/
25 A/50 A/
37.5 A/50 A
75 A/100 A
15.4 V
±25 mV/°C
–0.75 V – +0.25 V
DSP-EM
9600002565
9 – 35 Vg
170 mA
40 mA
fig. f
DSP1224C
DSP2024C
6.25 A/
12.5 A/25 A/
12.5 A/
37.5 A/50 A
18.75 A/25 A
30.8 V
+20 °C
±50 mV/°C
–1.5 V – +0.5 V
13
SinePower
EN