Troubleshooting - Dometic DSP1212C Instrucciones De Montaje Y D’uso

Inversor sinusoidal con cargador de batería integrado
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 99

Troubleshooting

13
Troubleshooting
13.1
Inverter
!
WARNING!
Do not open the device. You risk sustaining an electric shock by doing
this.
I
NOTE
If you have detailed questions on the specifications of the device
please contact the manufacturer (addresses on the back of the instruc-
tion manual).
The LED (fig. 2 2, page 1) indicates the fault:
LED display
Cause
Quick flash
Input voltage is too high Check the input voltage and reduce it.
Input voltage too low
2 s lit, short
Overheating
interruption
Excessive load
Off
Other fault
26
Remedy
The battery needs recharging.
Check the cables and connections.
Switch off the device and the consumer.
Wait 5 to 10 minutes and switch the device on
again without any electric consumers.
Reduce the load and make sure the device
has better ventilation. Then switch the
consumer back on.
Switch off the device and remove the
consumer.
Then switch the device back on without the
consumer. If no excessive load is now shown,
then there is a short circuit in the consumer or
the total load was higher than the power
specified on the data sheet.
Check the cables and connections.
Press in the AC breaker in the device by hand.
Contact the service.
SinePower
EN

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido