Connecting the device

• For ambient temperatures higher than 40 °C (such as in engine or heating
compartments, or direct sunlight), the device may shut down although the
connected load is below the rated load (derating).
• The device must be installed on a level and sufficiently sturdy surface.
A
NOTICE!
Before drilling any holes, make sure that no electrical cables or other
parts of the vehicle can be damaged by drilling, sawing and filing.
8.3
Mounting the device
➤ Mount the device as shown (fig. 5).
8.4
Mounting the DSP-EM
➤ Mount the DSP-EM as shown (fig. 6).
9
Connecting the device
9.1

General instructions

!
WARNING!
• The device may only be connected by a qualified workshop. The
following information is intended for technicians who are familiar
with the guidelines and safety precautions to be applied.
• Never use the device on vehicles where the positive terminal of the
battery is connected to the chassis.
• If you do not fit a fuse to the positive cable, the cables can over-
load, which might result in a fire.
• When installed in vehicles or boats, the device must be connected to the chassis
or earth.
• When setting up a socket distribution circuit (mains setup), comply with the
applicable regulations.
• Only use copper cables.
• Keep the cables for the DC connection as short as possible (<1 m).