Tripp-Lite APS Serie Manual Del Propietário

Ocultar thumbs Ver también para APS Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

200711151 93-2751 120V APS OM.qxd
APS Series
DC-to-AC Inverter/Chargers
Input
Invert:
12, 24, 36 or 48 VDC
Charge:
120V, 60 Hz. AC
Reliable Emergency Backup Power
Congratulations! You've purchased the most advanced, feature-rich Inverter/Charger designed as an alternative energy source during utility
power failures. Tripp Lite APS Inverter/Chargers keep your equipment constantly up and productive through all utility power problems (blackouts,
brownouts and high voltages) by inverting DC power from user-supplied batteries into AC power. Built-in surge suppression provides an additional
level of equipment protection. When utility power is present, APS Inverter/Chargers automatically pass through power to your equipment while
simultaneously recharging your connected battery bank. APS Inverter/Chargers are the quiet alternative to gas generators during emergency
backup applications-with no fumes, fuel or noise to deal with! You get AC electricity anywhere and anytime you need it.
Better for Your Equipment
Better for Your Batteries
Better for You
11/29/2007
2:47 PM
Owner's Manual
PowerVerter
®
Output
120V, 60 Hz. AC
12, 24, 36 or 48 VDC
2
3
4
5
6-7
8
* Available on all models except 612 models. ** Inverter/Chargers are moisture-resistant, not waterproof.
®
Copyright © 2007. PowerVerter
Page 1
Premium Protection Levels
• Built-In Isobar
Surge Protection
®
• Automatic Overload Protection
Ideal Output for All Loads (including computers)
• Frequency-Controlled Output
• Fast Load Switching
• Balanced Load Sharing*
Faster Battery Recharge
• High-Amp, 3-Stage Battery Charger (adjustable)
Critical Battery Protection
• Battery Charge Conserver (Load Sense)*
• Battery Temperature Sensing*
• High-Efficiency DC-to-AC Inversion
Simple, Maintenance-Free Operation
• Multi-Function Lights & Switches
• Moisture-Resistant Construction**
Contents
is a registered trademark of Tripp Lite. All rights reserved.
1111 W. 35th Street, Chicago, IL 60609 USA
Customer Support: (773) 869-1234
www.tripplite.com
9
10
11
11
12
13

Publicidad

Capítulos

Tabla de contenido
loading

Resumen de contenidos para Tripp-Lite APS Serie

  • Página 1: Tabla De Contenido

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 1 Owner’s Manual PowerVerter ® APS Series DC-to-AC Inverter/Chargers 1111 W. 35th Street, Chicago, IL 60609 USA Input Output Customer Support: (773) 869-1234 Invert: 12, 24, 36 or 48 VDC 120V, 60 Hz. AC www.tripplite.com Charge: 120V, 60 Hz.
  • Página 2: Specifications

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 2...
  • Página 3: Important Safety Instructions

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 3 Important Safety Instructions SAVE THESE INSTRUCTIONS! This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite Inverter/Chargers. Location Warnings •...
  • Página 4: Feature Identification

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 4 Feature Identification Identify the premium features on your specific model and quickly locate instructions on how to maximize their use. Configuration DIP Switches: optimize Inverter/Charger Resettable Circuit Breakers: protect your Inverter/Charger operation depending on your application.
  • Página 5: Operation

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 5 Operation Switch Modes LOAD Red Indicator: This red light will ILLUMINATE CONTINUOUSLY whenever the After configuring, mounting and connecting your Inverter/Charger, you inverter is functioning and the power demanded by are able to operate it by switching between the following operating connected appliances and equipment exceeds 100% modes as appropriate to your situation:...
  • Página 6: Configuration

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 6 Configuration Set Configuration DIP Switches Using a small tool, set the Configuration DIP Switches (located on the front panel of your unit, see diagram) to optimize Inverter/Charger operation depending on your application. 612 models have one set of four DIP Switches (Group A). All other models include an additional set of four DIP switches (Group B) to configure additional operational functions.
  • Página 7 200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 7 Configuration (continued) Least Limiting (#B1 Up & #B2 Down): Select Battery Charger-Limiting Points—OPTIONAL (Not on 612 Models) Charger-limiting begins at when the Inverter/Charger’s load reaches 66% of the Most Limiting (#B1 & #B2 Up, factory Inverter/Charger’s load rating.
  • Página 8: Battery Selection

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 8 Battery Selection Select Battery Type Select “Deep Cycle” batteries to enjoy optimum performance from your Inverter/Charger. Batteries of either Wet-Cell (vented) or Gel-Cell /Absorbed Glass Mat (sealed) construction are ideal. 6-volt “golf cart,” Marine Deep-Cycle or 8D Deep-Cycle batteries are also acceptable. You must set the Inverter/Charger’s Battery Type DIP Switch (see Configuration section for more information) to match the type of batteries you connect or your batteries may be degraded or damaged over an extended period of time.
  • Página 9: Mounting

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 9 Mounting WARNING! Mount your Inverter/Charger BEFORE DC battery and AC power connection. Failure to follow these instructions may lead to personal injury and/or damage to the Inverter/Charger and connected systems. Tripp Lite manufactures a variety of different Inverter/Chargers with a variety of different mounting options for use in vehicular or non-vehicular applications.
  • Página 10: Battery Connection

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 10 Battery Connection Connect your Inverter/Charger to your batteries using the following procedures: • Connect Inverter/Charger is capable of delivering Lug to the vehicle’s chassis or earth ground. Though peak wattage at up to 200% of its rated See the Feature Identification section to locate Wiring: your...
  • Página 11: Ac Input/Output Connection

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 11 AC Input/Output Connection To avoid overloading your Inverter/Charger, be sure to match the power requirements of the equipment you plan to run at any one time (add their total watts) with the output wattage capacity of your Inverter/Charger model (see Specifications). When figuring the power requirements of your equipment, do not confuse “continuous”...
  • Página 12: Troubleshooting/Warranty

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 12 Troubleshooting Try these remedies for common Inverter/Charger problems before calling for assistance. Call Tripp Lite Customer Service at (773) 869-1234 before returning your unit for service. Battery Indicator Lights Operating Mode Switch (GREATER (LESSER Operation Indicator Lights...
  • Página 13: Español

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 13 Manual del Propietario PowerVerter ® Serie APS Inversores/cargadores de corriente continua a corriente alterna 1111 W. 35th Street, Chicago, IL 60609 USA Soporte al cliente: (773) 869-1234 Entrada Salida www.tripplite.com Inversión: 12, 24, 36 o 48 VCC 120V, 60 Hz.
  • Página 14: Especificaciones

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 14...
  • Página 15: Instrucciones De Seguridad Importantes

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 15 Instrucciones de seguridad importantes ¡GUARDE ESTAS INSTRUCCIONES! Este manual contiene instrucciones y advertencias importantes que deben seguirse durante la instalación, operación y almacenamiento de todos los inversores/cargadores de Tripp Lite. Advertencias de ubicación •...
  • Página 16: Identificación De Funciones

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 16 Identificación de funciones Identifica las funciones Premium en su modelo específico y ubica rápidamente las instrucciones para optimizar su utilización. Conmutadores DIP de configuración: optimizan la operación de su Interruptores automáticos restaurables: protegen su inversor/cargador inversor/cargador en función de su aplicación.
  • Página 17: Operación

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 17 Operación Modos de conmutación Indicador rojo LOAD (carga): Esta luz roja se ILUMINARÁ Después de la configuración, el montaje y la conexión de su inversor/cargador, CONTINUAMENTE siempre que el inversor esté puede operarlo cambiando a los siguientes modos de operación, según funcionando y que la energía requerida por los aparatos y corresponda:...
  • Página 18: Configuración

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 18 Configuración Fijar conmutadores DIP de configuración Usando una herramienta pequeña, fije los conmutadores DIP de configuración (ubicados en el panel frontal de su unidad, vea el diagrama) para optimizar la operación del inversor/cargador en función de su aplicación.Los modelos 612 tienen un conjunto de cuatro conmutadores DIP (Grupo A) Todos los otros modelos incluyen un conjunto adicional de cuatro conmutadores DIP (Grupo B) para configurar funciones adicionales de operación.
  • Página 19 200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 19 Configuración (continuación) Seleccionar cargador de batería-Puntos límite—OPCIONAL Mínima limitación (#B1 arriba y #B2 abajo): (No en los modelos 612) La limitación del cargador comienza cuando la carga del inversor/cargador alcanza el Mayor limitación (#B1y #B2 arriba, ajuste de 66% de su capacidad total de carga.
  • Página 20: Selección De Baterías

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 20 Selección de batería Seleccionar Tipo de batería Seleccione baterías de "ciclo profundo" para disfrutar de un óptimo rendimiento de su inversor/cargador. Las baterías de fabricación de celda húmeda (con venteo) o de celda de gel /AGM (Absorbed Glass Mat) (sellada) son las ideales.Las baterías de 6 voltios "golf cart," Ciclo profundo tipo Marino o Ciclo profundo 8D también son aceptables.
  • Página 21: Montaje

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 21 Montaje ¡ADVERTENCIA! Monte su inversor/cargador ANTES de conectar la batería de corriente continua y la energía de corriente alterna. No seguir estas instrucciones puede producir lesiones personales y/o daños al inversor/ cargador y a los sistemas conectados.
  • Página 22: Conexión De La Batería

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 22 Conexión de batería Conecte su inversor/cargador a sus baterías usando los siguientes procedimientos: • Conexión continua y permite la máxima transferencia de tierra. Vea la sección Identificación de funciones cableado de corriente corriente.
  • Página 23: Servicio/Mantenimiento

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 23 Conexión de entrada/salida de corriente alterna Para evitar sobrecargar su inversor/cargador, asegúrese de cumplir los requisitos de potencia del equipo que planea operar en cualquier momento a la vez (sume sus potencias totales) con la capacidad de potencia de salida del modelo de su inversor/cargador (vea la sección Especificaciones) Cuando estime los requisitos de potencia de su equipo, no confunda potencia "permanente"...
  • Página 24: Solución De Problemas/Garantía

    200711151 93-2751 120V APS OM.qxd 11/29/2007 2:47 PM Page 24 Solución de problemas Pruebe estas soluciones para problemas comunes del inversor/cargador antes de llamar para ayuda técnica. Llame a Servicio al cliente de Tripp Lite, al (773) 869-1234 antes de enviar su unidad para servicio. Luces indicadoras de batería Conmutador de modo de operación (LESSER...

Tabla de contenido