4
Installation and connection
4.1
Installation planning
A
The illustration shows an example of a lighting system. Variations are possible.
• Only connect the LED spotlight to components with compatible connections.
• It is possible to add spotlights to the lighting system if a more powerful switching power pack with additional
outputs is used.
• Switching power pack requirements:
− Electronic switching power pack with DC decoupling between the primary and secondary side.
− Output voltage: 24 V DC
− Residual ripple: Max. 5 %
• Caption:
DMX capable LED spotlights
Hybrid extension cable:
3 m length (50728)
7.5 m length (56403)
Connection cable 24 V DC:
1 m length (12762)
3 m length (12552)
7.5 m length (12553)
15 m length (11720)
Connection cable DMX:
1 m length (12368)
3 m length (12369)
10 m length (12372)
20 m length (12373))
4.2
Set-up the unit
The unit can be placed submerged or dry.
How to proceed:
1.
0.
C, D
• Fasten the unit to a suitable base using 4 screws (not included in the scope of delivery).
• Fasten the PowerBox 24V DC to a suitable foundation using 2 screws.
• Fasten the DMX box to a suitable foundation using 2 screws.
4.3
Connecting the spotlights
Note!
• Do not exceed the max. connected load. (→ Technical data)
• Adhere to the max. cable length per output (→ Technical data)
• Only connect cables from OASE to the outputs.
• Close off any unused slots with blind plugs and rubber seals.
How to proceed:
1.
0.
C, E
8.
Remove the protection cap from the unit.
9.
Fit the connector of the connection cable and secure with the two screws (max. 2.0 Nm).
− Ensure that the rubber seal is clean and fits exactly.
− Replace the rubber seal if damaged.
10. Connect further connection cables in the same way.
- GB -
19