replacing the belt with another original VIRUTEX belt.
Assemble the toothed belt (Fig. 9), turning it clockwise
while simultaneously moving it towards the inside.
Be careful to mesh it correctly with the teeth of the
pulley without forcing it.
12. MAINTENANCE OF
BRUSHES AND COLLECTOR
Always remove the plug from the mains
socket before carrying out any work
on the machine.
The brush must be replaced when worn out as follows:
Take off the cover R (Fig. 1) by removing the four
screws holding it in place.
To change each brush, move the end of the spring
T (Fig. 10) backwards and keep it in this position.
Remove the worn brush and replace it with another
original VIRUTEX brush.
Ensure that it slides smoothly within the guide and
release the spring T over the brush.
Replace the cover R (Fig. 1) with its screws.
If possible, leave the machine running for 15 minutes
to ensure that the brushes are correctly adapted.
Should you detect burns or ribbing
on the collector, have it repaired at a
VIRUTEX technical service outlet.
13. NOISE AND VIBRATION LEVEL
The noise and vibration levels of this device have
been measured in accordance with European stan-
dard EN 60745-2-14 and EN 60745-1 and serve as
a basis for comparison with other machines with
similar applications.
The indicated vibration level has been determined
for the device's main applications and may be used
as an initial value for evaluating the risk presented
by exposure to vibrations. However, vibrations
may reach levels that are quite different from the
declared value under other application conditions,
with other tools or with insufficient maintenance
of the electrical device or its accessories, reaching a
much higher value as a result of the work cycle or
the manner in which the electrical device is used.
Therefore, it is necessary to establish safety measures
to protect the user from the effects of vibrations,
such as maintaining both the device and its tools
in perfect condition and organising the duration
8
of work cycles (such as operating times when the
machine is subjected to loads, and operating times
when working with no-load, in effect, not in use, as
reducing the latter may have a considerable effect
upon the overall exposure value).
14. WARRANTY
All VIRUTEX power tools are guaranteed for 12 months
from the date of purchase, excluding any damage
which is a result of incorrect use or of natural wear and
tear on the machine. All repairs should be carried out
by the official VIRUTEX technical assistance service.
VIRUTEX reserves the right to modify its products
without prior notice.
F R A N Ç A I S
RABOT CE120P
(Voir images p. 26, 27, 28, 29)
1. INSTRUCTIONS DE SÉCURITÉ
POUR LE MANIEMENT DU RABOT
Avant d'utiliser le rabot CE120P,
lire attentivement la BROCHURE
D'INSTRUCTIONS GÉNÉRALES DE SÉ-
CURITÉ jointe à la documentation de
la machine.
S'assurer avant de brancher la machine que la tension
d'alimentation correspond à celle indiquée sur la
plaque de caractéristiques.
Porter des lunettes de sécurité pour travailler avec
cette machine.
Maintenir les mains éloignées de la zone de coupe
et toujours prendre la machine par la poignée avec
les deux mains.
Éviter de couper des clous. Vérifier la surface à
travailler avant de la raboter.
Débrancher la machine du secteur avant de faire
toute opération d'entretien.
Toujours employer des couteaux d'origine VIRUTEX.
Ne jamais employer de couteaux qui ne seraient pas
affûtés, ayant des dimensions incorrectes, défectueux
ou en mauvais état.
Toujours utiliser le porte-lames et les supports de
lames d'origine VIRUTEX montés sur la machine.