DESCRIPTION OF THE DEVICE
The device consists of the following main components (please see inside cover):
1.
Display with touch-sensitive control panels
2.
Steam outlet (hot!)
3.
Water level window
4.
Cover (rear side)
5.
Housing
6.
Operating mode display
No Water: «low water»
12. Magnetic catch
13. Water tank
14. Power cable with Hygrostat sensor (do
not cover)
15. Tank lid
16. Upper steam pipe
STARTING UP / QUICK GUIDE
This quick guide helps practised users to start the device in a few steps. For detailed start-up
instructions, please consult the next chapter.
1.
Place the humidifier on a stable and watertight surface, never
on a carpet or parquet floor.
2.
Take off the cover (4) at the rear side (magnetic catch). Re-
move the water tank (13). Hold the water tank firmly by the
handle, swivel outwards and pull it upward.
3.
Turn the tank upside down. Unscrew and remove the tank lid
(15).
4.
Fill the tank with no more than 3.5 litres (0.92 US gallons) of
cold fresh water.
12
7.
ON/OFF power key
8.
OUPUT: Steam output
9.
HUMIDITY: Air humidity
10. TIMER: Timer mode
11. NIGHT MODE: Night mode
17. Lower steam pipe
18. LED display
19. Water level sensor
20. Water collector
21. Vaporizing plate
2.
1.
5.
Screw the tank lid (15) firmly onto the tank.
6.
Turn the tank upside down and check for water leakage.
7.
Install the tank, and you should hear a bubbling sound (water
collector filling).
8.
Replace the water tank lid (4): first attach to the underside and
then swivel until the magnetic catch (12) holds in place.
9.
Insert the power plug («ON/OFF» is displayed).
10. As soon as the water collector is completely full, the red display
«No Water» goes out. The humidifier is now ready to use.
11. Switch on the device: by touching the «ON/OFF» key. The display
will show «ON» briefly followed by the current humidity, e.g. «41».
Shortly after this, the sound of the water boiling can be heard
and hot steam will be emitted. Do not touch. Danger of scalding!
12. To set the humidity: set the desired humidity by repeatedly
touching the «HUMIDITY» key, (35–75 % rel.). We recommend
40- 60 %. As soon as the display shows the current relative air
humidity, the humidity setting is saved and automatically moni-
tored. Set «CO» for continuous operation without humidity moni-
toring, but this may cause excess humidity if used too often.
13. Set the desired humidifying capacity: by repeatedly touching
the «OUTPUT» key (1= low, 3 = high).
14. Activate the automatic shutdown: by repeatedly touching the
«TIMER» key. Adjust the shutdown time in hours (01-12 hours,
or «00» for no timer).
15. Night mode: touch the «NIGHT MODE» key to dim the light.
Switch off function by touching any function key.
1./2.
3.
1.
2.
5.
Speed Humidity Timer
Night
No Water
ON/OFF
OUTPUT
HUMIDITY
TIMER
NIGHT MODE
11.–15.
13