Flotec FP5712 Manual Del Usuario página 6

Bomba de refuerzo de varias etapas
Ocultar thumbs Ver también para FP5712:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical
Risk of electric shock . Can shock, burn or kill. Disconnect power before working on pump, motor,
pressure switch, or wiring.
Motor Switch Settings
Dual-voltage motors (motors that can operate at either
115 or 230 volts), are set at the factory to 230 volts. Do
not change motor voltage setting if line voltage is 230
volts, or if you have a single voltage motor.
NOTICE Never wire a 115 volt motor to a 230 volt line.
Remove Motor End Cover
If you have a dual-voltage motor, and will connect it to
115 volts, follow the procedure below.
End Cover Screws
Motor
End Cover
Figure 5 – Removing Motor End Cover.
You will need to remove the motor end cover to change
the voltage setting.
Your motor terminal board (located under the motor end
cover) should look like one of those below.
Plug Type Voltage Selector
Ground
Screw
Voltage Change
Plug
Figure 6 – Voltage set to 230 volts, Plug Type.
For parts or assistance, call Flotec Customer Service at
To change to 115 volts:
1. Make sure power is off.
2. Pull the plug straight up.
3. Move and attach the plug at the 115 volt position.
4. Attach the power lead wires to the power lead
5. Attach the ground wire to the green ground screw
6. Reinstall the Motor end cover
Go to Wiring Connections.
Dial Type Voltage Selector
4693
Figure 7 – Voltage set to 230 volts, Dial Type.
To change to 115 volts:
1. Make sure power is off.
2. Turn the dial counter-clockwise until 115 shows in
3. Attach the power lead wires to the power lead
4. Attach the ground wire to the green ground screw
Power Lead
5. Reinstall the Motor end cover
Terminals
Go to Wiring Connections.
4694
The plug will now cover two metal tabs. The arrow
on the plug will point to 115V.
terminals. Make sure the wires are secure.
Ground
Screw
Voltage
Change Dial
the dial window.
terminals. Make sure the wires are secure.
800-365-6832
6
Power Lead
Terminals
4695

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fp5722Fp5732

Tabla de contenido