application of the adhesive weight on the
image, press the Enter button
rise it and then the Exit button
3. Using the arrows
limetre by millimetre to find the centre of the
plane selected for application of the adhesive
weight. When the correct position has been
found, confirm by pressing the Enter button
and then the Exit button
4. press and hold down the button
turn the wheel clockwise or anticlockwise to
change the position of the laser point until the
centre of the surface selected for the appli-
cation of the adhesive weight is illuminated.
Release the button to store the new position.
Repeat the procedure to change the second
balancing surface if necessary, otherwise exit
the programme using the exit key
.
Note: the balancing planes where the adhesive
weights are to be applied may be selected by the
user according to the specific shape of the rim.
However, bear in mind that it is always prefer-
able to select balancing planes as far apart as
possible in order to reduce the quantity of the
weight to be applied; if the distance between
the two planes is less than 37 mm (1.5"), the A
64 message is displayed.
-
Select the first side to be balanced.
-
Rotate the wheel until the central element of
the corresponding position indicator lights
up.
-
Apply the balancing weight in the position
indicated on the screen.
-
Repeat the operations listed for the second
side of the wheel.
62
Application of spring balancing
to memo-
-
Select the plane where the balancing weight
.
is to be applied.
-
Turn the wheel until the central part of the
move mil-
corresponding position indicator lights up
or press the centre of the round indicator to
start the automatic position search.
-
Place the clip weight in the 12 o'clock position.
.
-
Select the plane where the balancing weight
then
is to be applied.
-
Turn the wheel until the central part of the
corresponding position indicator lights up
or press the centre of the round indicator to
start the automatic position search.
-
The internal laser pointer automatically comes
out indicating the exact position for applying
the adhesive weight.
-
in this phase, if the balancing position is NOT
correct, it can be changed by pressing and holding
down the button
clockwise or anticlockwise to change the position
of the laser point until the centre of the surface
selected for the application of the adhesive
weight is illuminated. Release the button to store
the new position.
WARNING
The previously described procedure determines
the possible unbalance variation displayed by
the machine on both surfaces, therefore it is
recommended to apply the weights after the
balancing position is changed.
-
Apply the adhesive weight as indicated in the
figure.
weights
Application of adhesive
balancing weights
EYE LIGHT - Operator's manual
then turning the wheel