Descargar Imprimir esta página

Bosch ACS 651 Manual Original página 87

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 193
4.7
Operator list
Execute the following procedure to add a name to the
to the operator list.
i
Select the operator name prior to each A/C service.
1. In the ACS Settings menu, select "Operator List"
2. Press E.
3. Select the user to be changed with o or u
4. Press
to alter the name of the user.
5. Enter the operator name in the "Name" field and
press E.
6. Press c thrice to return to the main menu.
i
Operator names can only be entered using the
English alphabets on the keypad irrespective of
the language that you have selected.
length of the strings that can be entered is 30 char-
acters.
i
A maximum of 15 operator names can be added to
the list. To add another name, an existing name has
to be overwritten.
Robert Bosch GmbH
4.8
To change the default settings, execute the following
procedure.
In the ACS Settings menu, select "System Defaults"
and press E.
"
The System Defaults menu is displayed.
4.8.1
!
The quantity calculation of oil - delta or absolute - is
set at the factory. This setting can be changed be-
fore performing the service. Selecting the wrong oil
quantity might damage the compressor. Bosch can-
not accept liability for any material damage resulting
from incorrectly set parameter values.
!
Refer to chapter 10 for more details on delta oil and
absolute oil.
1. In the menu System Defaults, select "Automode
Service Parameters" and
2. Select the type of compressor oil - PAG or POE.
i
Check whether the type of fresh oil bottle corresponds to
the selection made in step 2 before proceeding with the
service.
!
The maximum
Hybrid vehicles are equipped with electric compressors.
Use of PAG oil damages the electric compressor.
Commissioning | ACS 651/751 | 87
Changing the system defaults
Automode Service Parameters
press E.
1 689 988 238
en
|
2012-11-06

Hide quick links:

Publicidad

loading

Este manual también es adecuado para:

Acs 751