Observe the legal requirements of your country for accident prevention and check
the device in regular intervals.
Unless otherwise specified, we recommend that an expert carries out an external
test every 2 years and an internal test every 5 years as well as a strength test every
10 years.
Faults
Use only original spare and accessory parts.
Fault
No pressure builds up in
the device
Liquid flows out of the
pump
No tank pressure
indication on the piston
pressure gauge, Safety
valves blow off too early.
Contact address for additional information → see title page.
Warranty
We guarantee that from the time it is first purchased for a period of the legally valid requi-
red warranty period (maximum 3 years) this device will not exhibit any material or proces-
sing errors. If defects are discovered during the warranty period, the manufacturer or the
distributor in your country will repair the device without charging for the labor or material or
(at the discretion of the manufacturer) replace the device itself or its defective parts. If such
defects are discovered, please contact us immediately. We require the invoice or cash
register receipt for purchase of the device. The warranty does not include wearing parts
(seals, O-rings, diaphragm, etc.) or defects, which have occurred due to improper use or
unforeseeable circumstances.
Declaration of Conformity
Products which belong to the PROFI 3270 . . series satisfy the requirements of the Pressure
Equipment Directive 2014/68/EU and carry the CE mark.
The data and illustrations in these instructions for use are for orientation only and not
binding in any way. The manufacturer reserves the right to make changes or improvements
to the products if these are considered appropriate without having to notify customers
owning a similar model about this fact.
1218
Cause
The pump is not screwed on
tightly.
O-ring [12] on the pump is
faulty. (Fig. 14)
Diaphragm [13] is defective.
(Fig. 14)
Valve disc [14] dirty of defec-
tive. (Fig. 15)
Piston pressure gauge [6] is
defective (Fig. 16)
Original operating instructions
15
Remedy
Screw the pump on tightly.
Replace the O-ring.
Replace the diaphragm.
Clean or replace the valve disc.
Replace the piston pressure
gauge.