FIRST USE / OPERATION
Please note: never transport the device with a full water tank.
Possible hazards:
too much water from water tank comes into the Main Base (12), this overloaded water level
• •
will cause dramatic reduction of mist output of the device.
water can easily come out from the Main Base (12).
• •
the water tank can fall off from the Main Base (12) and get damaged due to the heavy weight
• •
from the water (and water can leak on to the floor).
For this reason, Main Base (12) of the Stylies GALAXY humidifier should be placed first
1.
with empty Water Tank ( 2/11 ) in a suitable location.
When the device is in the desired location: Fill Water Tank ( 2/11 ) with fresh water and
2.
screw the Tank Cover (14) back on firmly and check that it is sealed properly. Place Water
Tank on base.
Plug Power Cable (13) into the power socket.
3.
Switch on the device by pressing the On/Off switch
4.
trol display appears blue.
Caution: If the red «Low water» warning
Check the water level in the tank. It may take several minutes to refill the water collector (21) if
necessary (the red light
then goes out).
The Mist Cap (1) can be turned 360° to have an even distribution of moisture. Never point
5.
the nozzle at walls or furniture, etc.
On the Display panel (8), it shows the current humidity level in the room, e.g.. «45 % RH».
6.
The desired air humidity level can be selected by pressing the humidity button
trol Panel. Settings are in 5% stages from 45 % to 75 % rel. air humidity. «CO» means contin-
uous operation without automatic control. We recommend 45-60 % rel. air humidity for living
areas.
When the «Auto» light (7) stops flashing, the setting has been saved and the current air humid-
ity is displayed again. The humidifier starts automatically as soon as the humidity is lower than
the setting, and stops when it is higher.
Note: If «CO» (continuous operation) is set, the humidifier WILL NOT STOP OR RESTART auto-
matically.
Press this key
to set the mist quantity in three stages (1 = low, 3 = high).
7.
Press thy key
to dim the LED light. Press it again to turn the light on.
8.
«Timer»-key
for setting the time until automatic shutdown. (Press in 1-hour steps, e.g. «2:00»
9.
for two hours). The display then shows «Timer» (5). The display goes out after reaching shut-
down time. Possible settings: «1:00 - 12:00» hours, or «0:00» to quit timer.
10. «Low water» warning: this red LED lights up if the water collector is empty or too low. In this
case turn off the «On/Off» power switch and fill the tank with fresh water. Then replace the tank
ln the base and turn the power on again.
Note: When you remove the tank, some water will flow out of the decalcifier cartridge. Then
turn the tank upside down and carry it with the lower handle (16). To prevent damage, always
turn off the power when the «Low water» warning lights up.
16
on the Control Panel (4), the con-
lights up, the humidifier cannot be switched on.
on the Con-

CLEANING PROCEDURE

Switch off the device and unplug the power cable from the socket before all maintenance
• •
work and after each use.
Never submerge the device in water (this can result in short-circuiting). To clean the device,
• •
simply wipe it with a damp cloth and then dry it thoroughly. Always ensure the power cable
has been unplugged beforehand.
Descale the humidifier as appropriate for the hardness of the water, but at least once a
• •
week: First remove the water tank and clean it with a brush. Descale the water collector
(22) in the base with a standard descaler and then rinse it thoroughly. Make sure no water
penetrates inside. Reassemble the device completely before use.
Remove the mist chamber (23) by gently turning anticlockwise and lifting. Also remove the
• •
beige outlet basket (25). Thoroughly rinse both components, and reassemble in the opposite
order. Make sure the mist chamber is firmly seated.
Thoroughly rinse out the water tank on a regular basis.
• •
Replace Descaler Cartridge (15) every 1-2 months as appropriate for the hardness of the
• •
water.
Descaler Cartridge and Water Hardness
The life-span of the cartridge is dependent on the hardness of the water. This can be
• •
tested using the test strip supplied (the test strip is placed on the reverse side of this
instruction manual).
Dip the test strip into the water for one second.
• •
After approx. one minute, the result can be seen on the measuring strip. Some of the
• •
green areas will change their colour to pink. The number of pink areas corresponds to the
hardness of the water.
Example: If there are three pink areas, the water has a hardness of «3».
• •
Number of
Water
Hardness (°dH) Cartridge needs replacing
pink areas
hardness
0/1
soft
from 4°dH
2
medium
from 7°dH
3
slightly hard
from 14°dH
4
very hard
from 21°dH
A simple test can be carried out to determine whether the cartridge is functioning correctly:
• •
hold a small mirror in the mist coming out from the unit for a few seconds. If a white deposit
has been left on the mirror (a sign of lime scale), the cartridge needs to be replaced.
Silver Cube
Before attaching the water tank, insert the «Silver Cube» in the base in the position (20)
indicated. (the «SilverCube» is works fitted).
The «Silver Cube» with its patented technology prevents the growth of bacteria and germs. It can
be used for a maximum of one season, and must be replaced at the start of the next heating
season (i.e. when the weather becomes cold). Despite using the «Silver Cube», you should replace
the water on a daily basis.
after days/litres
(approx for 3 litres per day)
120 days / 360 litres
60 days / 180 litres
40 days / 120 litres
20 days / 60 litres