Never touch the ultrasonic membrane (inside the device) when the device is in operation. The
•
membrane's oscillations can cause injuries similar to burns.
•
Do not add anything to the water (fragrances, essential oils or water fresheners).
Do not place the device directly on the loor. Use a water-proof underlay.
CLEANING PROCEDURE
•
Switch of the device and unplug the power cable from the socket before all maintenance work
and after each use.
•
Never submerge the device in water (this can result in short-circuiting). To clean the device,
simply wipe it with a damp cloth and then dry it thoroughly. Always ensure the power cable has
been unplugged beforehand.
•
Descale the humidiier as appropriate for the hardness of the water, but at least once a week:
First remove the water tank (the upper section) and clean it with a brush. Descale the device
with a standard descaler and then rinse it thoroughly. Reassemble the device completely be-
fore use.
•
Thoroughly rinse out the water tank on a regular basis.
•
Replace ilter cartridge (10) every 1-2 months as appropriate for the hardness of the water.
FILTER CARTRIDGE AND WATER HARDNESS
•
The life-span of the cartridge is dependent on the hardness of the water. This can be tested
using the test strip supplied (The test strip is adhered to the reverse side of this instruction
manual).
Dip the test strip into the water for one second.
•
•
After approx. one minute, the result can be seen on the measuring strip. Some of the green
areas will change their colour to pink. The number of pink areas corresponds to the hardness
of the water.
Example: If there are three pink areas, the water has a hardness of "3".
•
Number of
pink areas
0/1
2
3
4
A simple test can be carried out to determine whether the cartridge is functioning correctly: hold a
small mirror in the steam for a few seconds. If a white deposit has been left on the mirror (a sign of
lime scale), the cartridge needs replacing.
IONIC SILVER CUBE™ (OPTIONAL)
Before attaching the water tank, insert the Ionic Silver Cube™ in the base in the position indicated.
The Ionic Silver Cube™ with its patented technology prevents the growth of bacteria and germs. It
can be used for a maximum of one season, and must be replaced at the start of the next heating
season (i.e. when the weather becomes cold).
Despite using the Ionic Silver Cube™, you should replace the water on a daily basis.
10
Water
Hardness
hardness
(°dH)
soft
ab 4°dH
medium
ab 7°dH
Slightly hard
ab 14°dH
Very hard
ab 21°dH
Cartridge needs replacing
after days/litres
(for 3 litres per day)
approx. 120 days
approx. 360 litres
approx. 60 days
approx. 180 litres
approx. 40 days
approx .120 litres
approx. 20 days
approx. 60 litres