Rockwell Automation Allen Bradley InView Serie Manual De Instalación página 11

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 84
10
InView Marquee Message Display
Stacking
bracket
Screw
Remove
these
screws.
Next sign
Stacking bracket
Bottom sign
Publication 2706-IN006E-EN-P
Stacking
Up to 4 signs can be hung together vertically
TIP
("stacked"). Mounting system for stack mounting
must support a minimum of four times the total
weight of all signs being stacked.
Possible crush hazard. Do not stack more than 4
WARNING
signs. Otherwise signs may fall causing serious injury
or death.
!
1. Remove the top screw from each end cap of the bottom sign, as
shown in Step 1 of the Ceiling Mounting instructions on page 9.
2. Using the screw removed in Step 1, screw a stacking bracket to
each end cap, countersunk side out. Torque to 2.7 Nm (24
in-lb).
3. Remove the top and bottom screws from each end of the
remaining signs.
4. For each end of the signs, secure the stacking bracket from the
bottom sign to the next sign using one of the screws removed in
Step 3. Torque to 2.7 Nm (24 in-lb).
5. Secure a ceiling bracket to the top of each end cap on the top
sign, using Step 2 of the Ceiling Mounting instructions on page 9.