Rockwell Automation Allen Bradley InView Serie Manual De Instalación página 4

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 84
3. Insert the power wires through the left conduit hole on either
the top or the bottom of the sign. The bottom conduit hole is
recommended to reduce noise from power wires crossing serial
wires.
Use watertight conduit connectors only.
TIP
Flexible conduit should be used.
Internal
serial wires
Internal wiring for
power supply
4. Strip the wires back 1/4". Connect the incoming electrical wires.
Be sure to place the wires so they are not caught by screws
when replacing the power supply cover, and also so they do not
interfere with fan operation.
Hot (Line 1)
N
H
Ground
Neutral
(Line 2)
5. Insert the serial wires through the right conduit hole on either
the top or the bottom of the sign.
InView Marquee Message Display
Insert the
power wires
into one of
these
conduits.
Ground
Line
GREEN
(Hot)
w/
100 – 240 VAC
@ 50/60 Hz
Insert the
serial wires
Publication 2706-IN006E-EN-P
3
Neutral
(Line 2):

Publicidad

Tabla de contenido
loading

Tabla de contenido