InView Marquee Message Display
Changing the Serial
Address

Checkout Procedure

Electrical Connections
2706-P42, 2706-P43 and
2706-P44
Hole plugs, left,
removed
Publication 2706-IN006E-EN-P
A serial address for an InView sign is a number from 1 to 254 in
hexadecimal (01 to FE). All signs leave the factory with a default
address of 1 or 01.
The serial address is set in the messaging software and downloaded to
the display with the InView applications.
After installing a sign according to the Electrical and Mounting
Instructions, make sure the sign is installed properly by applying
power to it. The following information should be displayed on the
sign:
• firmware part number and version letter (e.g., xxxx),
• amount of RAM in the sign, (e.g., 256K), and
• serial address of the sign (a number from 01 to FE or from 1 to
254).
Connecting the power wires
ATTENTION
!
1. Remove the power supply cover by unscrewing its 6 screws.
Save the screws for a later step.
2. It is recommended that you install power and serial wires at the
bottom of the power supply enclosure. However, to
accommodate power or serial wire installation at the top of the
enclosure, you may want to remove the left or right conduit hole
plug from the top of the enclosure by removing its wing nut
inside the enclosure. Save the hole plug for a later step.
Hole plugs,
top, removed
Wing nuts for
hole plugs
Hazardous voltage. Contact with high voltage may
cause death or serious injury. Always disconnect
power to sign prior to servicing.