EN
9. PROGRAMMING
To access programming, press button F for 2 seconds.
Programming is divided into 4 levels.
To go to the next level keep key F pressed and press the + key (Sequence 1-2-3-1.......).
After selecting the desidered level, press push button F to display the functions available in consecutive order. Each F pression corre-
sponds to a function ( - - - .....)
With the function set, use the
Changes made to the parameters are active immediately but will be saved when exiting the menu, selecting the function with key
F.
PLEASE NOTE: All changes will be lost in case of black-out during when programming phases .
x 2"
F
1st level
programming
+
+
F
2nd level
programming
+
+
F
4th level
programming
+
+
F
Control unit
9.1 BASIC FUNCTIONS
-
+
or
key to change the values of the parameters (
Selects each single
F
1st level function
(see table par.8.2)
Selects each single
F
2nd level function
(see table par.8.3)
Selects each single
F
4th level function
(see table par.8.5)
Example:
Selecting Output2 on closed boom:
A
B
x 2"
+
+
F
F
F
2
nd
level
+
Changes the values
-
+
of each single 1st
level function
(see table par.8.2)
F
Changes the values
-
+
of each single 2nd
level function
(see table par.8.3)
F
Changes the values
-
+
of each single 4th
level function
(see table par.8.5)
F
C
D
x 5
x 4
+
=boom closed
- 24 -
-
: ---... /
: ...---).
F
F
E
x 3
F
-
+
"" function
Exit and save
programming