8. PROGRAMMING

To access programming, press button F for 2 seconds.
Programming is divided into 4 levels.
To go to the next level keep button F pressed and press the + key (Sequence 1-2-3-4-1.......).
After selecting the level wanted, press button F to display the functions available in consecutive order. Each time F is pressed the menu shifts
to the next function ( -  - .....)
With the function selected, use the
The changes made to the parameters are active immediately, but will be permanently saved only when exiting the menu, selecting the ST
function with key F.
NOTE: In case of power failure during programming, all changes will be lost.
x 2"
F
1st level
programming
+
+
F
2nd level
programming
+
+
F
4th level
programming
+
+
F
Control unit

8.1 BASIC FUNCTIONS

+
-
or
key to change the value of the parameter (
Selects each single
F
1st level function
(see table par.8.2)
Selects each single
F
2nd level function
(see table par.8.3)
Selects each single
F
4th level function
(see table par.8.5)
Example:
Selecting Output2 set to closed arm:
A
B
+
x 2"
+
F
F
F
2
nd
level
+
Changes the values
-
+
of each single 1st
level function
(see table par.8.2)
F
Changes the values
-
+
of each single 2nd
level function
(see table par.8.3)
F
Changes the values
-
+
of each single 4th
level function
(see table par.8.5)
F
C
D
x 5
x 4
+

=bollard closed
- 29 -
-
: ---... /
: ...---).
F
F
E
x 3
F

EN
-
+
"" function
Exit and save
programming