30" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
• Unlike the standard gas range, THIS COOKTOP
IS NOT REMOVABLE. Do not attempt to remove the
cooktop.
Special Instructions for appliances installed in the State
of Massachusetts: This appliance can only be installed in
the State of Massachusetts by a Massachusetts licensed
plumber or gas fitter. When using a flexible gas connector,
it must not exceed 3 feet (36 inches) in length. A "T"
handle type manual gas valve must be installed in the gas
supply line to this appliance.
1.

Power Supply Cord Kit

The user is responsible for connecting the power supply
cord to the connection block located behind the back
panel access cover.
This appliance may be connected by means of
permanent "hard wiring" (flexible armored or
nonmetallic shielded copper cable), or by means of a
power supply cord kit. Use only a power supply cord kit
rated at 125/250 volts minimum and marked for use
with ranges. Cord must have either 3 or 4 conductors.
For mobile homes, new installations, recreational
vehicles, or areas where local codes do not permit
grounding through neutral, a 4 conductor power supply
cord kit rated at 125/250 volts and marked for use with
ranges should be used (see Figure 4).
1. A 3-wire or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on
a separate circuit fused on both sides of the line
(time-delay fuse or circuit breaker is recommended).
DO NOT fuse neutral. The fuse size must not exceed
the circuit rating of the appliance specified on the
nameplate.
2. Use a circuit breaker of 20 Amp with a minimum
wire gauge #12AWG.
Terminals on end of wires must either be closed loop or
open-end spade lugs with upturned ends. Cord must
have strain relief clamp.
Range Connection Opening Size Chart
Refer to chart below for proper range connection opening size and
power supply cord kit ampere rating information. See serial plate on
range for kilowatt rating data.
See Serial Plate on Range
for KW Rating
120/240 Volts 120/208 Volts
0-16.5 Kw
0-12.5 Kw
(Model with Electric Oven and Gas Cooktop)
Minimum
Diameter (inches) of
Cord kit
Range Connection
Ampere
Opening
Rating
Cord Kit
Direct Connection
40 Amp
1-3/8 in.
1-1/8 in.
2.
Junction Box or Wall
Receptacle Location
Suggested location of the junction box or wall
receptacle is showed in Figure 1.
If a service cord is used, the wall receptacle should be
located in accordance with the dimensions below.
10"
(25.4 cm)
7" Max.
(17.8 cm Max.)
Locate Electrical Hook-up
Inside Shaded Area
3.

Electrical Connection to the Range

This appliance is manufactured with the neutral terminal
connected to the range.
While connecting range, do not
loosen the nuts which secure the terminal block
to the range. Electrical failure or loss of electrical
connection may occur.
Note: Refer to the wiring diagram at the end of this
manual.

Electrical Shock Hazard

• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until
appliance is permanently grounded.
• Disconnect power to the circuit breaker or fuse
box before making the electrical connection.
• This appliance must be connected to a
grounded, metallic, permanent wiring system,
or a grounding connector should be connected
to the grounding terminal or wire lead on the
appliance.
• Do not use the gas supply line for grounding
the appliance.
Failure to do any of the above could result in a
fire, personal injury or electrical shock.
3
Center
Line of
Range
W A L L
Center
Line of
Range
Figure 1