5.

Application

PROTRONIC - A3000 open non-touch, opto-electronically controlled WC flush valve
DN 20 for concealed installation, with facility for externally controlling options such
as fitting settings and communication via ECC function controller. Split-second
adjustment for flushing duration.
Electronic module with additional input for sensors (buttons) to be provided by the
customer, maximum distance to the electronic module 5 m.
Control functions:
– Time-controlled hygiene flushing, optionally with fixed interval or after a certain
defined time after last usage
– Simultaneity suppression
Additional functions with ECC function controller (Ethernet):
– Safety switch-off
– Cleaning system shut-down
6.

Technical Specifications

Minimum flow pressure:
Recommended flow
pressure:
Calculation flow rate:
Flushing flow:
Flush water volume:
Operating voltage:
Power consumption:
Communication:
Type of protection:
7.

ID 12200

1.2 bar
1.2–4.0 bar
1.0 l/s
1.0–1.3 l/s
6-9 l adjustable
24 V DC
3.5 W
Ethernet via ECC function controller
IP 68
- 5 -