Filter Scaler; Led Indication; Cutoff Distance; Hysteresis Mode - CARLO GAVAZZI LD30BI10BPIO Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 95

2.6.9. Filter Scaler

This function can increase the immunity towards unstable targets and electromagnetic disturbances: Its value
can be set from 1 to 255, the default factory setting is 1. The filter functions as a moving average. This means
that a filter setting of 1 gives the maximum sensing frequency and a setting of 255 gives the minimum sensing
frequency.

2.6.10. LED indication

The LED indication can be configured in 3 different modes: Inactive, Active or Find my sensor.
Inactive: The LEDs are turned off at all times
Active: The LEDs follow the indication scheme in 5.1.
Find my sensor: The LEDs are flashing alternating with 2Hz with 50% duty cycle in order to easily locate
the sensor.

2.6.11. Cutoff distance

Range 0...2000 (mm)
Measured distance beyond Cutoff distance, will be truncated to Cutoff distance.
Cutoff distance value will also be used when an object cannot be detected.

2.6.12. Hysteresis mode

See 2.4.1.3. Hysteresis Settings

2.6.13. Auto hysteresis value

See 2.4.1.3. Hysteresis Settings
23
Rev.00 - 01.2020 | LD30 IO-Link manual ENG | © 2020 | CARLO GAVAZZI Industri

Publicidad

Tabla de contenido
loading

Tabla de contenido