7.2.4. Sensor specific adjustable parameters (continued)
Parameter Name
SSC1 Hyst Mode
SSC1 Auto hysteresis value
AutoHysteresisValueSP1
AutoHysteresisValueSP2
7.2.5. Diagnostic parameters
Parameter Name
Operating Hours
Number of Power Cycles
Maximum temperature
– All time high
Minimum temperature
- All time low
Maximum temperature since
power-up
Minimum temperature since
power-up
Current temperature
Detection counter SSC1
Minutes above Maximum
Temperature
Minutes below Minimum
Temperature
Download counter
32
Rev.00 - 01.2020 | LD30 IO-Link manual ENG | © 2020 | CARLO GAVAZZI Industri
Index Dec
Access
(Hex)
80 (0x50)
R/W
81 (0x51)
-
1 (0x01)
R
2 (0x02)
R
Index Dec
Access
(Hex)
201 (0xC9)
RO
202 (0xCA)
RO
203 (0xCB)
RO
204 (0xCC)
RO
205 (0xCD)
RO
206 (0xCE)
RO
207 (0xCF)
RO
210 (0xD2)
RO
211 (0xD3)
RO
212 (0xD4)
RO
214 (0xD6)
RO
Default value
1=Auto
-
-
-
Default value
0
0 ... 2 147 483 647 [h]
0
0 ... 2 147 483 647
0
0
-
-
-
-
0 ... 2 147 483 647
-
0 ... 2 147 483 647 [min]
-
0 ... 2 147 483 647 [min]
0
Data range
Data Type
0=Manuel
Uinteger
1=Auto
-
RecordT
1 ... 1100 [mm]
Uinteger
1 ... 1100 [mm]
Uinteger
Data range
Data Type
IntegerT
IntegerT
-50 ... 150 [°C]
IntegerT
-50 ... 150 [°C]
IntegerT
-50 ... 150 [°C]
IntegerT
-50 ... 150 [°C]
IntegerT
-50 ... 150 [°C]
IntegerT
IntegerT
IntegerT
IntegerT
0 ... 65 536
UIntegerT
Length
8 bit
2x16 bit
16 bit
16 bit
Length
32 bit
32 bit
16 bit
16 bit
16 bit
16 bit
16 bit
32 bit
32 bit
32 bit
16 bit