2.6. Sensor Specific adjustable parameters

Besides the parameters directly related to output configuration, the sensor also have various internal parameters
useful for setup and diagnostics.

2.6.1. Selection of local or remote adjustment

It is possible to select how to set the sensing distance by either selecting the Trimmer or Teach-by-wire using the
external input of the sensor, or to disable the potentiometer to make the sensor tamperproof.

2.6.2. Trimmer data

Value between 30...1100 mm.

2.6.3. Process data configuration

When the sensor is operated in IO-Link mode, the user has access to the cyclic Process Data Variable.
By default the process data shows the following parameters as active: 16 bit Analogue value, Switching
Output1 (SO1) and Switching Output 2 (SO2).
The following parameters are set as Inactive: SSC1, SSC2, DA1, DA2, TA, SC.
However by changing the Process Data Configuration parameter, the user can decide to also enable the status
of the inactive parameters. This way several states can be observed in the sensor at the same time.

2.6.4. Sensor application setting

The sensor has 3 sensor application presets, which can be selected depending of application:
• Fast configuration (Filter scaler fixed to 1)
• Precise configuration (Filter scaler fixed to 10 - slow)
• Customized configuration (Filter scaler can be set from 1-255)
Precision can be adjusted via parameter "Filter scaler". See 2.6.9.

2.6.5. Temperature alarm threshold

The temperature at which the temperature alarm will activate can be changed for the maximum and minimum
temperature. This means that the sensor will give an alarm if the maximum or minimum temperature is exceeded.
The temperatures can be set between -50 °C to +150 °C. The default factory settings are, Low threshold -30
°C and high threshold +120 °C.
Rev.00 - 01.2020 | LD30 IO-Link manual ENG | © 2020 | CARLO GAVAZZI Industri