Sensor Specific Adjustable Parameters - CARLO GAVAZZI LD30BI10BPIO Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 95

7.2.4. Sensor specific adjustable parameters

Index Dec
Parameter Name
Selection of local/remote
68 (0x44)
adjustment
Trimmer value
69 (0x45)
Process data configuration
70 (0x46)
Analogue value
1 (0x01)
Switching Output 1
2(0x02)
Switching Output 2
3 (0x03)
Switching Signal Channel 1
4 (0x04)
Switching Signal Channel 2
5 (0x05)
Temperature alarm
6 (0x06)
Short-circuit
7 (0x07)
Sensor Application pre-set
71 (0x47)
Temperature Alarm Threshold
72 (0x48)
High Threshold
1 (0x01)
Low Threshold
2 (0x02)
Event Configuration
74 (0x4A)
Temperature fault event
1 (0x01)
(0x4000)
Temperature over-run
2 (0x02)
(0x4210)
Temperature under-run
3 (0x03)
(0x4220)
Short circuit (0x7710)
4 (0x04)
Quality of Teach
75 (0x4B)
Quality of Run
76 (0x4C)
Rating
1 (0x01)
SignalLow
2 (0x02)
AmbientHigh
3 (0x03)
NoObjectDetected
4 (0x04)
TemperatureError
5 (0x05)
Filter scaler
77 (0x4D)
LED indication
78 (0x4E)
CutOffDistance
79 (0x4F)
Access
Default value
(Hex)
R/W
1 = Trimmer input
RO
R/W
R/W
1 = Analogue value Active
R/W
1 = Switching Output 1 Active
R/W
1 = Switching Output 2 Active
R/W
0 = SSC1 Inactive
R/W
0 = SSC2 Inactive
R/W
0 = TA Inactive
R/W
0 = SC Inactive
R/W
R/W
R/W
R/W
R/W
0 = Temperature fault
R/W
Error event - Inactive
0 = Temperature over-run
R/W
Warning event - Inactive
0 = Temperature under-run
R/W
Warning event - Inactive
0 = Short circuit
R/W
Error event - Inactive
RO
RO
RO
RO
RO
RO
RO
R/W
R/W
1 = LED indication Active
R/W
Data range
1 = Trimmer input
2 = Teach-by-wire
-
-
0 = Analogue value Inactive
1 = Analogue value Active
0 = Switching Output 1 Inactive
1 = Switching Output 1 Active
0 = Switching Output 2 Inactive
1 = Switching Output 2 Active
0 = SSC1 Inactive
1 = SSC1 Active
0 = SSC2 Inactive
1 = SSC2 Active
0 = TA Inactive
0 = SC Inactive
0 = Normal/defeat precision (fast)
0 = Normal
1 = High precision (slow)
2 = Customized (filter scaler)
-
70°C
-20°C
-
0 = Error event Inactive
1 = Error event Active
0 = Warning event Inactive
1 = Warning event Active
0 = Warning event Inactive
1 = Warning event Active
0 = Error event Inactive
1 = Error event Active
-
-
Sensor overall health check
-
[0-100] 100=best
0 = Signal OK
-
1 = Signal low
0 = ambient OK
-
1 = ambient high
0 = Object detected
-
1 = Object not detected
0 = Temperature OK
-
1 = Temperature outside min/max
1
0 = LED indication Inactive
1 = LED indication Active
2 = Find my sensor
1500
Rev.00 - 01.2020 | LD30 IO-Link manual ENG | © 2020 | CARLO GAVAZZI Industri
Data Type
0 = Disabled
UintegerT
30 ... 1 100
-
-
RecordT
-
-
-
-
-
-
1 = TA Active
-
1 = SC Active
UintegerT
-
RecordT
-30 ... 70°C
IntegerT
-30 ... 70°C
IntegerT
-
RecordT
-
-
-
-
0...100
UintegerT
0...100
UintegerT
-
-
-
-
-
limits
1...255
UintegerT
UintegerT
0 ... 2000
Uinteger
Length
8 bit
-
16 bit
-
-
-
-
-
-
-
8 bit
30 bit
16 bit
16 bit
16 bit
-
-
-
-
8 bit
16 bit
-
-
-
-
-
8 bit
8 bit
16 bit
31