Indesit I5GG1G K /EX Serie Manual De Instrucciones página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

! If the appliance is connected to liquid gas, the
adjustment screw must be fastened as tightly as
possible.
5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not extinguished.
Adapting the grill
Replacing the grill burner
nozzle:
1. Remove the oven burner
V
after loosening screw V (see
fi gure).
2. Unscrew the grill burner
nozzle using a special nozzle
socket spanner (see fi gure) or
I
preferably with a 7 mm socket
spanner, and replace it with a new nozzle that is
suited to the new type of gas (see Burner and nozzle
specifi cations table).
! Be careful of the spark plug wires and the
thermocouple tubes.
! The oven and grill burners do not require primary air
adjustment.
! After adjusting the appliance so it may be used with
a different type of gas, replace the old rating label with
a new one that corresponds to the new type of gas
(these labels are available from Authorised Technical
Assistance Centres).
Table of burner and nozzle specifications
Table 1
Burner
Diameter
(mm)
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
51
(Small)(A)
Oven
-
Grill
-
Nominal (mbar)
Supply
Minimum (mbar)
Pressures
Maximum (mbar)
Thermal power
By-Pass
kW (p.c.s.*)
1/100
Nominal
Reduced
(mm)
3,00
0,7
41
1,90
0,4
30
1,00
0,4
30
2.80
1.0
46
2,30
-
-
! Should the gas pressure used be different (or vary
slightly) from the recommended pressure, a suitable
pressure regulator must be fitted to the inlet hose in
accordance with current national regulations relating to
"regulators for channelled gas".
TECHNICAL DATA
Oven dimensions
(HxWxD)
Volume
Useful
measurements
relating to the oven
compartment
Power supply voltage
and frequency
Burners
ENERGY LABEL
and ECODESIGN
Gaz liquide
Gaz naturel
Nozzle
Flow*
Nozzle
1/100
g/h
1/100
(mm)
***
**
(mm)
87
218
214
128
69
138
136
104
50
73
71
78
80
204
200
119
75
167
164
114
28-30
37
20
25
35
45
34x38x44 cm
57 l
width 42 cm
depth 44 cm
height 17 cm
see data plate
may be adapted for use with any
type of gas shown on the data
plate, which is located inside the
flap or, after the oven
compartment has been opened,
on the left-hand wall inside the
oven.
EC Directives: 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
90/396/EEC dated 29/06/90 (Gas)
and subsequent amendments -
93/68/EEC dated 22/07/93 and
subsequent amendments -
2002/96/EC.
1275/2008 (Stand-by/ Off mode)
Regulation (EU) No 65/2014 supplemen-
ting Directive 2010/30/EU.
Regulation (EU) No 66/2014 implementing
Directive 2009/125/EC.
Standard EN 15181.
Standard EN 30-2-1
S S
A
R
Flow*
l/h
I5GG1G.K /EX
I5GG1G /EX
286
181
95
Ø180
S
267
219
A
R
20
17
25
I5MG1G /EX
GB
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

I5gg1g /exI5mg1g /ex

Tabla de contenido