3. Lift the searing side burner out of the grill.
4. Use 6 mm socket wrench or 6 mm nut driver to remove the
orifice. Replace with the Natural gas orifice.
orifice
IMPORTANT: Check that the orifice is properly installed inside of the
valve.
5. Reinstall the searing side burner. Make sure that the igniter is out of
the way to allow proper positioning of burner. Use Phillips screwdriver
to attach the mounting screws.
6. Use Phillips screwdriver to reattach the igniter and searing side
6 U
Philli
d i
burner plate.
7. Reinstall searing side burner cover. Use Phillips screwdriver to
attach mounting screws.
8. Open the manual shutoff valve in the gas supply line. The valve is
open when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
Test all connections using an approved noncorrosive
9.
leak-detection solution. Bubbles will show a leak. Correct any
leak found.
Record Conversion
1. The appliance nameplate is located inside the grill cabinet on
the left –hand cabinet side. With a permanent marker, check
the box next to Natural gas and mark through LP-Propane.
the box next to "Natural gas" and mark through "LP Propane "
In the last page of the Use and Care Guide, writer " Converted to
Natural Gas." Also record the conversion date and the
technician/company that performed the conversion.
Note: Place LP gas parts in plastic parts bag for future use and
keep with pack containing literature.
orifice
orifice
t
tt
h th i
it
d
Adjust High Flame Setting Screw
When converting from LP to Natural gas, you will need to adjust the
high flame setting screw for ideal burner flame height.
1. Remove each control knob for the main burners and side burner
1 Remove each control knob for the main burners and side burner
2. Use a flat-blade screwdriver to turn the high flame
setscrew counterclockwise approximate 90 degree.
i
id
3. Check that burner operates at the new high flame setting.
It may be necessary to adjust the screw setting slightly more to
get the ideal burner flame height.
19