Bedienungsanleitung / Operating Instructions / Instructions de service / Instrucciones de manejo
Elektromagnetventile / Solenoid Valves /
Electrovanne / Válvulas electromagnéticas
30.30.01.00418
EN
Technical data
Nominal diameter
Nominal flow m³/h
Connection
Weight kg
NO / NC / IMP
Body material
Power consumption 24 V DC
NO / NC
230 V AC
Power consumption 24 V DC
IMP
Vacuum
Pressure ventilation connection
Enclosure type
Media
Pressure connection
Direction of flow
Orientation
Operating Temperature
Switch function
Pressure media
Rated voltage
Drive
Duty cycle
Instructions for valves
The solenoid valves have sliding bearings which require no maintenance. Nevertheless, we recommend that you
include the valves in the normal regular maintenance of the plant. Depending on the operating conditions and the
inspection intervals, dirt may be deposited in the valve or wear of parts (seals, diaphragms, piston rings, spindles,
etc.) may occur. Attention should be paid to the type-specific installation parameters such as the direction of flow,
installation orientation, operating pressure, electrical and air-line connections. In order to ensure trouble-free
operation of the valves, the following points should be observed.
Installation
Before installing the valve, ensure that the piping is absolutely clean in order to prevent dirt from entering the valve.
Compare the values on the rating plate and in the data sheet with the actual operating values to ensure that the rated
values are not exceeded.
A dirt trap installed before the valve will improve the operational reliability and prevent blocking of the control lines in
the valve.
Ensure that the pipes in which the valve is to be fitted are correctly aligned and laid in accordance with the planning
drawings. Avoid undue stress on the valve body which could result from the use of unsuitable tools
and/or sealing materials. Use only tools of the correct size on the connection fittings. The piping should be laid such
that there is no transmission of force through the longitudinal axis of the valve.
The electrical connections are made with the appropriate plug connector. Before connecting, ensure that the
actual voltage matches the value specified on the rating plate. Observe the markings on the terminals, since incorrect
connection of the voltage can result in destruction of the valve.
Ensure that the valve is correctly grounded in order to prevent electric shocks.
The electrical operation of the valve should be tested before the medium is connected. The valve must click audibly
when the switching voltage is applied. Do not attempt to strip the valve while the voltage is present: this is dangerous
and will result in major damage in the case of AC solenoids.
The warranty becomes invalid of the installation instructions are not observed!
Always specify the valve type and the supply voltage in any inquiries.
Status 10.2015 / Index 01
EMVP 10
10 mm
10
3/8"
0,42 / - / -
Aluminum
-
NO (normaly open) / NC (normaly closed) / IMP (bipolar)
EMVP 10-25
Seite: 3 / 8
EMVP 15
15 mm
20
1/2"
0,39 / 0,39 / 0,55
8,2 VA
-1 to 0 bar
0 to 5 bar
IP 65
filtered air
2,5 to 10 bar / 1/8"
as marked
-5°C to 50°C
filtered and oiled air
24 V DC
230 V / 50-60 Hz AC
DC: solenoid / AC: solenoid with integrated rectifier
100% ED
J. Schmalz GmbH
Aacher Straße 29
D - 72293 Glatten
Tel +49 (0) 7443 / 2403 - 0
Fax +49 (0) 7443 / 2403 – 259
www.schmalz.com
schmalz@schmalz.de
EMVP 20
EMVP 25
20 mm
25 mm
40
90
3/4"
1"
0,37 / 0,37 / 0,55
0,52 / 0,52 / 0,68
Plastic
5 W
2,3 W / Valve
any