Pro Series VS FloPro™ Series Variable-Speed Pump
®
VS FloPro Controller Options
The VS FloPro pump can be operated by one (1)
of four (4) controllers: the JEP-R variable-speed
controller, the AquaLink RS controller (Rev O or later),
the AquaLink PDA (Rev 4.0 or later), or the AquaLink
Z4. The VS FloPro variable-speed pump communicates
with the controllers via a four-wire RS-485 interface.
Controller Installation Options
The VS-FHP1.0, VSFHP165JEP, VS-FHP2.0, &
VSFHP270JEP pumps come pre-configured for the
JEP-R variable-speed controller with DIP switch
settings pre-configured to work with this controller. The
VSFHP165AUT and VSFHP270AUT Pumps come
pre-configured for installation with the AquaLink RS,
AquaLink PDA, or AquaLink Z4.
To install with an AquaLink RS controller (Rev O
or later), an AquaLink PDA (Rev 4.0 or later), or an
AquaLink Z4:
1.
Remove power from the VS FloPro pump by
disconnecting the high voltage lines or by turning
off any breaker to which the VS FloPro pump
power is connected.
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in the variable-
speed pump electrical circuit before starting the procedure.
Failure to comply may cause a shock hazard resulting in
severe personal injury or death.
2.
Remove the access cover to complete electrical
connections to the motor.
3.
Slide dip switches 1 and 2 down to the OFF
position. If applicable to your pump model slide
dip switch 5 up to the ON position. See Figure 7.
4.
Select the desired address(es) for the pump by
setting dip switches 3 and/or 4, as shown in Section
3.3, VS FloPro Pump Dip Switch Settings.
5.
If short RS485 cable or JEP-R controller is pre
installed:
a. Disconnect the RS485 cable from the 4-pin
header on the pump drive.
Note: Do not cut the cable, or you will lose the ability to return
to the default factory configuration.
b. Connect the new RS-485 cable from the
AquaLink through the available compression
fitting and route the 4-conductor cable through
the motor drive threaded port closest to the
connector. Figure 7.
6.
Connect the RS-485 connector on the
AquaLink
RS (or multiplexer interface board),
®
matching wire colors with connector positions as
follows: 1-red, 2-black, 3-yellow, and 4-green. See
Figure 7.
WARNING
|
Installation & Operation Manual
7.
Restore power to the pump and verify the operation
of the controller.
8.
Refer to the appropriate manual for set up and
operation of the pump: AquaLink RS Owner's
Manual, 6593, AquaLink PDA Owner's Manual,
H0572300, or AquaLink Z4™ Owner's Manual,
H0386600.
AquaLink
5-Position
DIP Switch
200 ft (61 m)
max install distance
for communication
4-Position
DIP Switch
Figure 7.
Wiring AquaLink RS Controller or
AquaLink PDA
JEP-R Remote Mounting
The variable-speed controller may be remote mounted
onto a vertical surface that is protected from the
elements.
Follow the directions carefully to maintain the ability
to reinstall the variable-speed controller onto the Pump.
Reverse these instructions to complete the reinstallation.
See Figure 8.
Page 11
ENGLISH
®
RS RS-485 Connectors
4 3 2 1
4 3 2 1
6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
RS6 & RS8 ONLY
RS8 ONLY
S1
RESET
AUTO
SERVICE
HEATER
SOLAR
TIME OUT
S2
Connect to
AquaLink RS
4 3 2 1
RS-485 Connector
(or Multiplexer
Interface Board)
Variable-Speed
Pump
Power Wiring
Port
Product may differ from images shown
POOL MODE
SPA MODE
SPA DRAIN
SPA FILL