Appendix C
SPECIFICATIONS
Cabinet:
Metal, weather-resistant, indoor/outdoor, wall mount with key-actuated
locking cover
Dimensions:
10.75" W x 9.5" H x 5.75" D
(27.3cm W x 24.1cm H x 14.6cm D)
Wiring/Conduit Provision:
Power Wiring - 1/2" NPT end bell nipple
Field Wiring - 2" (52mm) diameter conduit access
Power Specifications, Domestic Model:
Input – 120 V a.c., 60 Hz, 0.5A
Output – 24 V a.c., 60 Hz, 30 VA (max. total), 0.5A (max. per station)
Power Specifications, International Model:
Input – 230 V a.c., 50 Hz, 0.5A
Output – 24 V a.c., 50 Hz, 30 VA (max. total), 0.5A (max. per station)
Power Specifications, Australian Model:
Input – 240 V a.c., 50 Hz, 0.5A
Output – 24 V a.c., 50 Hz, 30 VA (max. total), 0.5A (max. per station)
Sensor Input: Normally-closed rain switch (override switch provided)
Master Valve/Pump Start Relay Output: 24 V a.c., 0.5A (maximum)
Battery: 9-volt, Alkaline
Fuse: 250V, 2.0A, Slow-Blow (extra fuse provided)
Temperature Limit Specifications:
Operating – 32°F to 140°F (0°C to 60°C)
Storage – -22°F to 149°F (-30°C to 65°C)
Specifications