Twin-Star International 35HF500GRA-ESP Manual De Instrucciones página 6

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FIREPLACE LOCATION
When choosing a location for your new fireplace,
ensure that the general instructions are followed.
Also, for best effect, install the fireplace out of
direct sunlight.
Cold climate installation recommen-
dation: when installing this unit
against a non-insulated exterior wall
or chase, it is mandatory that the
outer walls be insulated to conform
to applicable insulation codes.
ELECTRICAL CONNECTION
A 15 AMP, 120 Volt, 60 Hz circuit with a properly
grounded outlet is required. Preferably, the fireplace
will be on a dedicated circuit as other appliances on
the same circuit may cause the circuit breaker to trip
or the fuse to blow when the heater is in operation.
The unit comes standard with 6 feet (1.8 m) three
wire cord, exiting from the rear of the fireplace.
Plan the installation to avoid the use of an extension
cord. If an extension cord must be
WARNING: Make sure the power is turned off before proceeding. Any electrical repairs or
rewiring of this unit should be carried out by a licensed electrician in accordance with
national and local codes.
If repairing or replacing any electrical component or wiring, the original wire routing, color
coding and securing locations must be followed.
WARNING: Electrical outlet wiring must comply with local building codes and other applicable
regulations to reduce the risk of fire, electrical shock and injury to persons.
WARNING: Do not use this fireplace if any part of it has been under water. Immediately call a
qualified service technician to inspect the fireplace and replace any part of the electrical system.
Warning: Disconnect power before attempting any maintenance or cleaning to reduce the risk
of fire, electrical shock or personal injury.
Warning: During any service of this appliance, the power to the unit must be turned off.
First turn the main power switch to the "OFF" position. Then remove the electrical plug from
the wall outlet.
used, it must be a minimum 14 AWG ; three wires
with grounding type plug connector and rated
not less than 1875 Watts. The cord shall not be
more than 20 feet (6 m) in length.
Keep electrical cords, drapery, furniture and other
combustibles at least 3 feet (0.9 m) from the front of the
heater and away from the sides.
Clean the metal trim using a soft cloth, slightly
dampened with citrus oil based product and buff with
a clean soft cloth. DO NOT use brass polish or
household cleaners as these products will damage
the metal trim. Citrus oil based products can be
obtained at supermarkets or hardware stores.
MAINTENANCE
MAINTENANCE
E-5
ELECTRICAL SPECIFICATIONS
Voltage:
120VAC, 60Hz
Amps:
12.5 Amps
Watts:
1500 Watts
CLEARANCE TO COMBUSTIBLES
CLEANING TRIM

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

35hf500gra-blk35hf500gra-oak

Tabla de contenido